Descargar Imprimir esta página

Vision Fitness ELLIPTICAL ERGOMETER S60 Manual Del Usuario página 122

Ocultar thumbs Ver también para ELLIPTICAL ERGOMETER S60:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 131
POWER REQUIREMENTS
SELF-POWERED FEATURE
S60/S70
Is a self-powered unit, requiring no external power source. When a
user pedals at a speed above 25 revolutions per minute (RPM), the
power is generated to allow the unit to function properly.
S70
If "Battery Low" displays on your console, you should plug the S70 into the wall
for 6 – 12 hours to recharge the battery fully. Be sure to turn the power switch
to the "On" position to charge the battery or to use plug-in feature.
DEDICATED CIRCUIT AND ELECTRICAL INFO
A "Dedicated Circuit" means that each outlet you plug into should not have anything else
running on that same circuit. The easiest way to verify this is to locate the main circuit breaker
box, and turn off the breaker(s) one at a time. Once a breaker has been turned off, the only
thing that should not have power to it are the units in question. No lamps, vending machines,
fans, sound systems, or any other item should lose power when you perform this test.
Non-looped (isolated) neutral/grounding means that each circuit must have an individual
neutral/ground connection coming from it, and terminating at an approved earth
ground. You cannot "jumper" a single neutral/ground from one circuit to the next.
ELECTRICAL REQUIREMENTS
By power adapter, output : 12 V DC, 5 A
ELECTRICAL REQUIREMENTS
For your safety and to ensure good unit performance,
the ground on this circuit must be non-looped
(isolated). Please refer to NEC article 210-21 and
210-23. Any alterations to the standard power cord
provided could void all warranties of this product.
Console accessories require an external power
supply. An external power supply will ensure
power is provided to the console at all times and is
required when add-on accessories are used.
For units with an integrated TV (Touch), the TV power
requirements are included in the unit. An RG6 quad shield
coaxial cable with 'F Type' compression fittings on each end will
need to be connected to the cardio unit and the video source.
110 V Units
110 V units require the use of a 100-125 V, 60 Hz and a
15 A "Dedicated Circuit" , with a non-looped (isolated)
neutral/ground for power. This outlet should be a
NEMA 5-15R and have the same configuration as the
plug. No adapter should be used with this product.
4
For S70/S600E/S700E
For S600E
For S70/S700E
110 NEMA 5-15P
PLUG (N.A.)
EURO PLUG
(EUROPE)
North American and
European power
cord plugs shown.
Depending on your
country, the plug
type may vary.
220 V Units
220 V units require the use of a 216-250 V, 50 Hz and a 15 A "Dedicated Circuit" , with a non-
looped (isolated) neutral/ground for power. This outlet should be a NEMA 6-15R and have
the same configuration as the plug. No adapter should be used with this product.
Grounding Instructions
The unit must be grounded. If it should malfunction or breakdown, grounding provides
a path of least resistance for electric current to reduce the risk of electric shock. The unit
is equipped with a cord having an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and ordinances. If the user does not
follow these grounding instructions, the user could void the limited warranty.
Additional Electrical Info
In addition to the dedicated circuit requirement, the proper gauge wire must be used
from the circuit breaker box, to each outlet that will have the maximum number of units
running off of it. If the distance from the circuit breaker box to each outlet, is 100 ft (30.5
m) or less, then 12 gauge wire should be used. For distances greater than 100 ft (30.5
m) from the circuit breaker box to the outlet, a 10 gauge wire should be used.
ENERGY SAVING / LOW-POWER MODE
All units are configured with the ability to enter into an energy saving / low-power mode when
the unit has not been in use for a specified period of time. Additional time may be required to
fully reactivate this unit once it has entered the low-power mode. This energy saving feature
may be enabled or disabled from within the 'Manager Mode' or 'Engineering Mode.'
FCC REGULATIONS (USA ONLY)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC RF Radiation Exposure Statement:
1. This Transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
For S60/S70/S600E/S700E
For S600E/S700E

Publicidad

loading

Este manual también es adecuado para:

22488