➥ Top up lubricator with SAE20 non-detergent oil.
Air leak inside the machine
Air leak from bead breaker cock.
➥ Replace the cock.
➥ Replace bead breaker cylinder.
Air leak from the table top cock.
➥ Replace turntable cylinder.
➥ Replace swivel connector.
Bead breaker cylinder lacks force, fails to break beads and leaks
air
Silencer plugged.
➥ Replace silencer
Cylinder gaskets worn.
➥ Replace seals.
➥ Replace bead breaker cylinder.
Bead breaker cylinder leaks air around the rod
Air gaskets worn.
➥ Replace seals.
➥ Replace bead breaker cylinder.
Turntable will not rotate in either direction
Inverter faulty.
➥ Replace inverter.
Belt broken.
UK
➥ Replace belt.
Gear unit clamped.
➥ Replace gear unit.
Gear unit noisy. The turntable makes 1/3 of a spin and then stops
Gear unit seizing.
➥ Replace gear unit.
Turntable fails to clamp rims
Turntable does not clamp rim.
➥ Replace turntable cylinder.
Clamp grippers are worn.
➥ Replace clamp grippers.
Turntable mounts or demounts wheels with difficulty
Insufficient belt tension.