6
Snubber
(210A)
(210)
W4
W4, energized whenever
1 Torch cutting is NOT
enabled, is de-energized
when 1 Torch is enabled
(W5 energized) to isolate
the automation tip from
the 1 Torch tip when
cutting with 1 Torch.
To NEG OUTPUT
BUSS BAR #49
Rev
Revision
AA
ECO-B2687
6
0-5264ES
7
Optional 1 Torch Module
(201)
(201)
1 Torch Contactor ON (24VAC)
1
+24VDC
(202)
(202)
2
(203)
(203)
/ Main Torch Idle
3
(204)
(204)
/ 1 Torch START
4
(205)
(205)
/1 Torch START Ret (Common)
5
(206)
(206)
/ 1 Torch Press OK Ret (Common)
6
(207)
(207)
/ 1 Torch Press OK
7
(208)
(208)
24 VDC (-)
8
(209)
(209)
24 VDC (+)
9
(210)
(210)
10
11
(212)
(212)
24 VAC Ret
12
(213)
(213)
24 VAC Ret
13
(214)
(214)
24 VAC
14
(215)
(215)
ELECTRODE
15
(216)
(216)
TIP
16
17
(213)
18
(219)
(219)
19
(220)
(220)
20
J86
(214)
ELECTRODE
TIP
(220)
(219C)
(219B)
10 AWG
(219A)
14 AWG
(220A)
(220B)
By
Date
Rev
Revision
By
DAT
10/20/2014
7
APÉNDICE
ULTRA-CUT 100 XT/200 XT/300 XT/400 XT
8
9
XT 1 TORCH MODULE
(202)
Relay under control of
(203)
D200
CCM isolates torch Start
wires (for noise) when
Automation cutting.
1N4007
PS2
(206)
(207)
K200
1A
35 PSI
(221)
(205)
(222)
(204)
(209)
D201
(208)
24 VDC coil
1N4007
K201
1A
Energized
with W5
Isolates
test ckt.
when W5
closed
SA200
Snubber
(212)
(201)
W5
*
W5 AUX
(210)
(212A)
D202
1N4007
1A
1000V
(219)
W5
10 AWG
(223A)
L4
T4
(223B)
L3
T3
(223C)
L2
T2
12 AWG
(224B)
L1
T1
1 Torch Module Component Locations
D200
Diode, 1A, 1kv
D201
Diode, 1A, 1kv
D202
Diode, 1A, 1kv
K200
Relay, DPDT, 24VDC coil
K201
Relay, DPDT, 24VDC coil
SA200
RC Snubber,
SA201
RC Snubber,
PS2
Pressure SW, 35 PSI, N. O
SOL4
Solenoid, 24VAC
W4
Contactor, Pilot Isolation,
40A 2P, 24VAC coil
W5
Contactor, 1 Torch Isolation,
40A 4P, 24 VAC coil
Date
The information contained herein is proprietary to Thermal Dynamics.
Not for release, reproduction or distribution without written consent.
Title
SCHEMATIC
XT 1 Torch Module & Interconnections
8
9
10
A
B
1TORCH SL100
C
w/ 100A Consumables
PIP SWITCH
ATC CONNECTOR
TORCH SWITCH
1
1
(225)
2
2
3
3
4
4
5
5
6
6
7
7
8
8
-
+
D
WORK
(A9)
(B9)
(C9)
(B9)
E
(B9)
(C8)
(B8)
(B8)
(B8)
(6B, E3)
(8D, 8C)
Art # A-12792_AB
Thermal Dynamics Corporation
2800 Airport Rd.
Denton, Texas 76207 USA
F
Date Printed
Date Revised
12/16/2014
11/20/2014
Drawn
Date
D Tatham
5/29/2014
Size
Sheet
C
1
1
of
Drawing Number
042X1366
10