Maintenance, Service, And Repairs; Replacing Lights - AHT MACAO Serie Manual De Instrucciones

Ocultar thumbs Ver también para MACAO Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 113
en | AHT Cooling Systems GmbH
Switch off cooling
Press
function (start de-
onds.
frosting manually)
Allow the appliance to defrost.
Remove the lid (see Setup and installation).
If required, take accessory parts out the inside
of the appliance (see → Setup and function).
Remove food residues (e.g. due to breakage of
packaging) and packaging residues. Remove
defrosting water.
Wet vacuum cleaner / electric appliance with
explosion protection mark
Lightly moistened, soft cotton cloth
Clean the defrosting drain.
Remove and clean the condensation water
sieve.
Fig. 9: Defrost water sieve (1), defrosting drain (2)
Clean the surfaces inside.
Dry all cleaned parts and surfaces. Correctly
reinstall accessory parts removed.
Properly install the lid (see → Setup and instal-
lation) and close it completely.
Switch on the cooling function (see → page 11,
chapter 5).
Press
Switch on the cool-
onds. The interior temperature
ing function
appears on the display.
Clean the floor around the appliance.
NOTICE
Property damage due to misuse.
Only add goods to the appliance once the
specified temperature for the product has
been reached.
Check the temperature display and display indicator
page 11, chapter 5.
12 Maintenance, service, and
repairs
Responsibility
Qualified staff
Only specialist personnel may carry out service and re-
pair work, including the following function tests.
The appliance does not need any regular maintenance.
In the event of questions relating to maintenance, contact
the maintenance service (see → Maintenance services).
405859_1_0819
for at least 3 sec-
appears on the display.
for at least 3 sec-

Maintenance, service, and repairs | 12

WARNING
Work on the electrical system and re-
frigerant circuit.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Fire haz-
ard due to sparking or overload.
Only qualified staff may carry out
work on the electrical system and re-
frigerant circuit.
Note safety instructions, page 7, chap-
ter 2.5.
Observe the electrical safety rules
prior to commencing work.
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
During the repair a competent per-
son with knowledge of local condi-
tions must be available as contact for
the qualified staff.
Only qualified staff may restart the
appliance and perform functional
tests.
CAUTION
Sharp edges, rotating parts. Hot sur-
faces.
Risk of injury to hand and body. Risk of burns
in the event of skin contact.
Only specialist personnel may carry
out service and repair work on the
appliance.
Use protective gloves.
Touch hot surfaces, in particular the
compressor, only after they have
cooled down.

12.1 Replacing lights

Responsibility
Qualified staff
If a light fails, contact the maintenance service (see →
Maintenance services).
Lights used
LED bars
For technical data, see → Technical data
WARNING
Work on the electrical system.
Contact with live parts may result in electric
shock.
Only qualified staff may replace
lights.
Observe the electrical safety rules
prior to commencing work.
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
43 / 505

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido