(Max depth
> MB level active
> No-stop time relative to L0
> Temperature
> (Max depth)...
)
NOTE:
Whereas the quantitative information relative to L0 can be seen by pressing the right
button, qualitative information is always visible on the display in form of the nitrogen
loading bar. In particular, when the L0 no-stop time is less than three minutes,
the nitrogen bar will flash ->27. This will help you avoid entering inadvertently into
decompression.
6.2.2 Display during level stop phase
Total ascent time
including level stops
DEPTH
DIVE TIME
STOP
CNS O
%
2
S
L
O
W
Level stop
depth
The deepest level
stop is displayed.
Level stop duration
The duration of a level stop
at a given level stop depth
is displayed.
(Max depth
6.3
Preparation for a dive
with MB levels
6.3.1 Setting the MB level
To change the MB level Aladin 2G must be
in user mode (time of day display).
or
SCUBAPRO ALADIN 2G
>) Temperature
and time of day
Time
Nitrogen
loading bar
relative to LO
->27
->26
35.7m
MB no-stop phase
>) Temperature
> MB level active
> No-stop time or deco information relative to L0
> Temperature
and time of day
> (Max depth)...
until
6. Diving with microbubble (MB) levels
Total ascent time (14min)
6m/20ft
9m/30ft
Level stop phase
To complete the dive without cascading
to a lower MB level all requested
level stops must be observed.
1. Push
or
until the symbol for
MB levels
appears.
2. Confirm that you wish to change the
displayed MB level by pushing
3. Change MB level by pushing
.
4. Confirm the selected MB level with
Without
confirmation
the
disappear after 3 minutes and your entries
will not be accepted.
Aladin 2G will display the
confirm that an MB level beyond L0 (L1-
L5) has been chosen. During the dive the
3m/10ft
Lowest level
stop depth
3min
Level stop duration
.
or
.
display
will
symbol to
39