Fault
The pump starts without
utility request.
The
water
pressure
turning on the utility is n
immediate (*).
When the utility is
turned on the flow falls to
zero before the pump
starts (*).
The display shows BL.
The display shows BP1.
The display shows OC.
The display shows PB.
(*) In case of installation of an expansion tank.

11. DISPOSAL

This product or its parts must be disposed of in an environment-friendly manner and in compliance with the local regulations
concerning the environment; use public or private local waste collection systems.

12. GUARANTEE

Any modification made without prior authorisation relieves the manufacturer of all responsibility. All the spare
parts used in repairs must be authentic and all accessories must be authorised by the manufacturer, in order to
ensure maximum safety of the machines and of the systems in which they may be installed.
This product is covered by a legal guarantee (in the European Community for 24 months from date of purchase) against
all defects that can be assigned to manufacturing faults or to the material used.
The product under guarantee may, at discretion, either be replaced with one in perfect working order or replaced free of
charge if the following conditions are observed:
the product has been used correctly in compliance with the instructions and not attempt has been made to repair it by
the buyer or by third parties.
the product has been consigned to the outlet where it was purchased, attaching a document as proof of purchase
(invoice or cash register receipt) and a brief description of the problem found.
The impeller and parts subject to wear are not covered by the guarantee. Intervention under guarantee does not extend
the initial guarantee period in any way.
LED
Red: off
White: on
Blue: off
whe
Red: off
White: on
Blue: off
Red: off
White: on
Blue: off
Red: on
White: on
Blue: off
Red: on
White: on
Blue: off
Red: on
White: on
Blue: off
Red: on
White: on
Blue: off
ENGLISH
Probable Causes
1.
Leak in the system.
2.
Faulty non-return valve.
Expansion vessel empty (insufficient air
pressure) or has broken diaphragm.
Air pressure in the expansion vessel
higher than the system starting pressure.
1.
No water.
2.
Pump not primed.
3.
Setpoint not reachable with the set
RM value.
1. Faulty pressure sensor.
1.
Excessive absorption.
2.
Pump blocked.
1.
Supply voltage too low.
2.
Excessive drop in voltage on the
line.
22
Remedies
1. Check the system, find and
eliminate the leak.
2.
Service
the
non-return
valve as described in par.
9.3.
Check the air pressure in the
expansion vessel. If water is
found to flow out during the
inspection, it means the tank is
broken
Otherwise
restore
the
pressure
according
equation P= SetPoint-1bar.
Set
the
expansion
pressure or configure the SP
and/or RP parameters in such a
manner
as
to
satisfy
equation P= SetPoint-1bar.
1-2. Prime the pump and check
whether there is air in the pipe.
Check whether the suction or
any filters are blocked.
3. Set a RM value that allows
the setpoint to be reached.
1.
Contact
the
assistance
centre.
1. Fluid too dense. Do not use
the pump for fluids other
than water.
2. Contact
the
assistance
centre.
1. Check the presence of the
correct supply voltage.
2. Check the section of the
power supply cables.
air
to
tank
the

Publicidad