Models ICB427 and ICB427R Installation
Anti-Tip Bracket Installation
An anti-tip bracket and hardware is provided with the wine
storage unit. The anti-tip bracket must be installed on a
solid base to prevent tipover in case several loaded wine
shelves are extended at the same time.
If you are installing the model ICB427 or ICB427R in a
space deeper than 610 mm, the anti-tip bracket must be
installed no more than 610 mm deep, so it engages the
unit properly. It is important that this measurement be
made from the front of the unit without panels, to the back
of the anti-tip bracket.
To prevent the unit from tipping forward and provide
a stable installation, install the anti-tip bracket and
extend the front leveling legs to the floor.
WOOD FLOOR APPLICATIONS
Use the six #12 x 64 mm wood screws and the six 6 mm
flat washers provided. Drill pilot holes 5 mm diameter
maximum, and be sure that the screws penetrate through
the flooring material and into the wall plate a minimum of
19 mm. Be sure that the screws hold tight. Refer to the
illustration below.
CONCRETE FLOOR APPLICATIONS
Use the two 10 mm x 95 mm concrete wedge anchors,
two #12 x 64 mm wood screws and two 6 mm flat
washers provided. Be sure that the anchors and screws
hold tight. Refer to the illustration below.
IMPORTANT NOTE: In some installations the subflooring
or finished floor may require angling the wood screws
used to fasten the anti-tip bracket to the back wall.
Make sure that there are no electrical wires in the
area which the screws could penetrate.
610
mm
C L
310
310
mm
mm
FINISHED FLOORING
Finished Flooring
UNDERLAYMENT
Underlayment
Wall Plate
WALL PLATE
SUBFLOORING
Subflooring
38
mm
CONCRETE
WOOD FLOOR
min
FLOOR
Wood floors—
Concrete floors—
dimension A is 343 mm.
dimension A is 343 mm.
CONCRETE WEDGE ANCHOR INSTALLATION
1) Drill a 10 mm diameter hole any depth exceeding the
minimum embedment. Clean the hole or continue
drilling additional depth to accommodate drill fines.
Use a carbide drill bit manufactured within ANSI
B94.12-77.
2) Assemble the washer and nut flush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is flush with
the surface material.
3) Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 34 newton meters of torque.
Always wear safety glasses and use other necessary
protective devices or apparel when installing or
working with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use
in new concrete which has not had sufficient time to
cure. The use of core drills is not recommended to
drill holes for the anchors.
subzero.com
Position Unit
IMPORTANT NOTE: For model ICB427R, the top drawer
has a control cable that needs to be disconnected before
removing this drawer. Refer to illustration 3 below for
placement and how to disconnect this fitting.
For model ICB427R, the drawers should be placed aside
until you are ready for installation of the door and drawer
panels.
IMPORTANT NOTE: When two models ICB427, ICB427R or
integrated units are installed closer than 51 mm to one
another, it is necessary to use the Sub-Zero dual installation
heater kit. The heater from this kit must be attached to the
left side exterior of the right-hand unit before the unit is slid
into position. The dual installation heater kit and additional
instructions is available through your Sub-Zero dealer.
Control cable.
11