Models ICB427 and ICB427R Installation
Model ICB427R Drawer Panels
IMPORTANT NOTE: Drawer panels for model ICB427R
must be a minimum of 16 mm thick and cannot exceed 5
kg for each panel.
Remove the mounting hardware provided and set aside.
You should work on the back side of each drawer panel
and you should protect the fronts of these panels.
Position the top edge of the drawer template flush with the
top edge of each drawer. For the top drawer, there is only
one place for the lower mounting bracket to be placed.
However, depending on the depth of the lower drawer
panel, you have two options for placement of the bracket.
Refer to the illustration.
Secure the template in place with tape or small clamps
and mark positions for your pilot holes. Remove template.
Drill pilot holes and place the hardware in the proper place
(dog-ear bracket on top) and fasten securely with the
#8 x 13 mm screws provided. Refer to the illustration.
To help with proper placement of drawer panels, examine
the lower panel mounting bracket and determine which
slotted holes to use. Position screws into the lower portion
of the drawer that correspond with these slotted holes.
Leave these screws out a small distance so they can help
when you mount the drawer panels to the drawer.
With the two brackets in place on the drawer panel,
engage the top dog-ear bracket first and then the lower
bracket onto the protruding screws. You will have a 6 mm
adjustment up and down and side to side in each drawer
panel. Fasten all screws to the lower bracket to secure the
drawer panel.
IMPORTANT NOTE: Once drawer panels have been
adjusted for proper spacing, be sure to reconnect the
control cable on the upper drawer after you have installed
the drawer. Refer to the illustration on page 11.
TOP OF TEMPLATE
FLUSH WITH TOP OF
DRAWER PANEL
GAP ON SIDE
EDGES WILL
VARY WITH
DESIGN
BACK OF
DRAWER PANEL
Template position.
Hardware
placement.
Side Panels
Side panels for models ICB427 and ICB427R are not
attached to the unit. You must securely fasten the panels
to adjacent cabinets and floor.
Panels should be fastened to the floor and walls using 'L'
brackets (hardware not provided). To help you move the
unit into place, rout out an area in the floor so the 'L'
bracket will sit flush with the floor level.
Anchoring
Brackets and screws are provided for mounting the unit to
adjoining cabinets and side panels. Each unit has four
side-mounting clips on each side.
IMPORTANT NOTE: For installations where you are not
attaching to a side wall, or you are installing two model
ICB427, ICB427R or integrated units together, you must
remove the side-mounting clips before moving the unit
into position. After removing the clips, replace the screws
into the appliance.
A dual installation heater kit (7007529) is necessary for
anchoring two model ICB427, ICB427R or integrated units
together. The kit is available through your Sub-Zero dealer.
90° Door Stop
Models ICB427 and ICB427R have a 90° door stop built
into the hinge system. Use the blade edge of a standard
screwdriver and rotate the brass cam in the center portion
of the hinge until you reach the stop. You must make this
adjustment to both the bottom and top hinge. Refer to the
illustration.
subzero.com
90° door stop.
Completing the Installation
IMPORTANT NOTE: When you have completed the instal-
lation of the model ICB427 or ICB427R wine storage unit,
refer to page 27 for an installation checklist and page 28
for service information.
15