Model ICBWS-30 Installation
Anti-Tip Bracket Installation
To prevent the unit from tipping forward and provide
a stable installation, the unit must be secured in place
with the anti-tip brackets shipped with the unit.
IMPORTANT NOTE: Placement of the anti-tip brackets is
critical to a stable installation. Failure to properly position
the anti-tip brackets will prevent them from engaging the
unit.
IMPORTANT NOTE: The two anti-tip brackets must be
installed exactly 610 mm from the front of the rough
opening to the back of the brackets and a minimum of 102
mm from the sides of the rough opening. This depth will
increase to 665 mm for a flush inset installation based on
19 mm deep decorative panels. Proper placement will
ensure that the anti-tip brackets engage the anti-tip bar at
the back of the unit.
Anti-Tip Hardware Included
2
Anti-tip brackets
12
#12 x 64 mm PH pan HD zinc screws
4
10 mm–16 x 95 mm wedge anchors
12
#12 flat washers
4
#8–18 x 32 mm PH truss HD screws
4
Nylon zip-it wall anchors
IMPORTANT NOTE: For either wood or concrete floor
applications, if the #12 x 64 mm screws do not hit a wall
stud or the wall plate in any of the back holes of the
brackets, use the provided #8–18 x 32 mm PH truss HD
screws and #12 flat washers with the nylon zip-it wall
anchors.
IMPORTANT NOTE: In some installations the subflooring
or finished floor may necessitate angling the screws used
to fasten the anti-tip brackets to the back wall.
WOOD FLOOR APPLICATIONS
After properly locating the anti-tip brackets in the rough
opening, drill pilot holes 5 mm diameter maximum in the
wall studs and/or wall plate. Use the #12 x 64 mm PH pan
HD zinc screws and #12 flat washers to secure the
brackets in place. Be sure that the screws penetrate
through the flooring material and into wall studs or wall
plate a minimum of 19 mm. Refer to the illustration to the
right.
CONCRETE FLOOR APPLICATIONS
After properly locating the anti-tip brackets in the rough
opening, drill pilot holes 5 mm diameter maximum in the
wall studs and/or wall plate. Then drill 10 mm diameter
holes into the concrete a minimum of 13 mm deep. Use
the #12 x 64 mm PH pan HD zinc screws and #12 flat
washers to secure the brackets to the wall and use the
10 mm–16 x 95 mm wedge anchors to secure the
brackets to the floor. Be sure that the screws penetrate the
wall studs or wall plate a minimum of 19 mm. Refer to the
illustration below.
Make sure there are no electrical wires or plumbing
in the area which the screws could penetrate.
610
mm
102 mm
102 mm
MIN
MIN
FINISHED
FINISHED
FLOORING
FLOORING
WALL
WALL
PLATE
UNDERLAYMENT
PLATE
UNDERLAYMENT
SUBFLOORING
SUBFLOORING
13 mm
WOOD FLOOR
CONCRETE
Wood floors.
Concrete floors.
INSTALL CONCRETE WEDGE ANCHORS:
1) Drill a 10 mm diameter hole any depth exceeding the
minimum embedment. Clean the hole or continue
drilling additional depth to accommodate drill fines.
Use a carbide drill bit manufactured within ANSI
B94.12-77.
2) Assemble the washer and nut flush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is flush with
the surface material.
3) Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 34 newton meters of torque.
Always wear safety glasses and use other necessary
protective devices or apparel when installing or
working with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use
in new concrete which has not had sufficient time to
cure. The use of core drills is not recommended to
drill holes for the anchors.
610
mm
MIN
20