ROSS EUROPA GmbH
• Robert-Bosch-Strasse 2 • D-63225 Langen
Telefon: (06103) 7597- 0 • Fax: (06103) 74694 • e-mail: info@rosseuropa.com • www.rosseuropa.com Sitz: Langen • AG: Langen, B412 •
Geschäftsführer: Ralf W. Dinkel

EU declaration of conformity

Product: ROSS® double valve MCSE
This declaration of conformity is issued under the sole responsibility of the manufacturer
are in full accordance with the following Directive:
Machinery Directive
2006/42/EC
EMC Directive
2014/30/EC
Applied harmonized standards:
EN ISO 13849-1: 2015:
Safety of Machinery
- Safety related parts of a control system -Part 1
EN ISO 13849-2: 2012:
Safety of Machinery
- Safety related parts of a control system -Part 2
EN ISO 60204-1: 2014-10:
Safety of Machinery
- Electrical equipment of machines -Part 1
DIN EN 61508-1-7: 2010/2011:
Functional Safety of electrical/ electronic/ programmable electronic safety-related
systems Part 1-7 (as applicable)
DIN EN 62061: 2016-05:
Safety of machinery – Functional safety of safety-related electrical,
electronic and programmable electronic control systems (as applicable)
EN 61000-6-2:2005:
Electromagnetic compatibility -: Generic standards - Immunity standard for
industrial environments (IEC 77/488/CDV:2015)
EN 61000-6-4:2007+A1:2011:
Electromagnetic compatibility -: Generic standards - Emission standard for
industrial environments
EN ISO 4414: 2010-11:
Pneumatic Fluid Power
General Rules and Safety Requirements for Pneumatic
Systems and their Components
Applied non-harmonized standards:
EN 61326-3-1: 2008:
Electrical equipment for measurement, control and laboratory use
– EMC requirements – Part 3-1
Tested in accordance to:
GS-IFA-M07:2017-04 (as applicable)
Authorized person for the compilation of technical documentation:
Andreas Jourdan
ROSS EUROPA GmbH
Robert-Bosch-Strasse 2
63225 Langen / Germany
Langen, 2019-06-16

1. About this Documentation

These instructions contain important information for the safe and appropriate assembly
and commissioning of the product.
f Read these instructions all the way through, particularly section  2. "Notes on
Safety", before working with the product.
Additional documentation:
SISTEMA libraries
DGUV (formerly BG) certificate: German professional association
Technical documents
For more information see last page for contact information, or visit www.rosscontrols.
com.
f In addition, observe all applicable local and national regulations on accident
prevention and on environmental protection.
1.1. Warning Notices in these Operating Instructions
In these operating instructions, warning notices precede sections with handling
requirements which incur risks of personal injury or material damage.
Warnings are structured as follows:
Type or source of hazard!
Consequences
f Measures to avert danger
Warning triangle: Indicates a risk of fatal or severe injuries.
Signal word: Indicates the severity of the danger.
4
© 2021, ROSS CONTROLS
®
(Original Version)
Signed for and on behalf of
Dietrich Warmbier
Global Safety Product Manager
SIGNAL WORD
. All Rights Reserved.
Type or source of hazard: States the type of danger or the source of the hazard.
Consequences: Describes possible consequences of ignoring the warning.
Measures to avert danger: Indicates how to avoid the danger. It is essential that
the measures to avert danger are complied with.
Indicates an imminent and serious danger that will result in severe or
DANGER
even fatal injury if you fail to avoid it.
Indicates a possible danger that could result in severe or even fatal
WARNING
injury if you fail to avoid it.
Indicates a danger that may result in minor to moderate injuries if you
CAUTION
fail to avoid it.
Indicates potential property damage that may be incurred by the
ATTENTION
product or its surroundings if you fail to avoid it.
2. Notes on Safety
The product has been manufactured according to the accepted rules of current
technology.
There is risk of injury or damage if the following safety instructions and warnings given
in this instruction manual are not observed.

2.1. Intended Use

The MCSE Series double valves are safety components designed and manufactured
in accordance with Machinery Directive 2006/42/EC. Its intended use is to control
ventilation and exhaust in compressed air systems or similar applications, as well as
to avoid unexpected switch-on and release of energy in pneumatic tubing systems and
end devices in the industry.
The MCSE Series double valves are designed for safe, redundant operation and have
internal monitoring. The valves consist of redundant 3/2 valves and have the overall
function of an externally piloted valve with spring return.
f See section 12 "Technical Data" for the standards and test values complied with
and adhered to by the product. See the declaration of conformity for product-
relevant directives.
Intended use includes having read and understood this documentation, especially the
chapter 2 "Notes on safety"
Soft Start
The MCSE Series double valves have a soft start function (soft start). The function of
the soft start module is that the output pressure increases slower than normal during
pressurization, until it reaches approx. 50% of the inlet pressure. The valve then opens
fully at this point and fills the system with the full flow rate. This feature can be used to
reduce the surge of a sudden, quick pressure application of cylinders. This function is
particularly useful when inline flow controllers are placed in the cylinder control lines.
By fully opening the soft start, the soft start function could be disabled if not needed.
2.1.1. Safety Function According to ISO 13849
The MCSE Series safety valve is a redundant system according to the requirements
of ISO 13849-1 and -2, in which the pneumatic safety functions "safe exhaust" and
"prevention of unexpected start-ups" are ensured, including in case of a safety valve
fault (e.g., due to wear).
The safety function of the 3/2 valve from the MCSE Series is that the machine/system
is only supplied with pneumatic energy (compressed air) when the redundant electrical
control and therefore both valve elements are actuated simultaneously. The supply
with compressed air is switched off and the system is exhausted if the redundant
electrical control is not available.
The MCSE safety valve is designed in such a way so that the safe state (filling switch-
off and exhausting the operating line) is always ensured, even in case of a fault within
the valve (e.g., due to wear, contamination or similar situations). The control outputs of
the electrical safety system must be designed and constructed in such a way that they
fulfill the requirements of the category and the performance level (PL) of the safety
system, which result from the machine's risk assessment. With correct integration in
the control system in accordance with ISO 13849-1 and -2, these products can be
used in up to Category 3 and 4 and a performance level up to e can be achieved.
The product has been engineered and manufactured according to the fundamental
and proven safety principles of ISO 13849-2.
2.1.2. Common Cause Failure – CCF
The product has been engineered and manufactured according to the fundamental
and proven safety principles of ISO 13849-1 and -2 (e.g., measures for the software,
diagnosis, against further CCF, against systematic failures etc.) and then evaluating
whether the necessary performance level has been achieved.
Common Cause Failures (CCF) are failures of different components, resulting from
a single event. CCF are not to be confused with cascading faults or common mode
faults. Common cause failures can cause loss of the safety function, especially in dual
channel circuits where both channels could fail simultaneously due to a single event.