Position the 3 grub screws or M8 threaded screws (pos. ,
Fig. 5) with the function of extractors in the holes and two
sufficiently long M10 screws with the function of supporting
the cover (pos. , Fig. 5).
Slowly screw in the 3 M8 screws (pos. , Fig. 6) with the
function of extractors to fully remove the cover unit and
pinion
Complete disassembly of the reduction gear cover from the
pinion is possible following these steps:
Remove the Seeger ring Ø120 (pos. , Fig. 7).
Separate the pinion from the cover, working with an extractor
hammer on the pinion itself (pos. , Fig. 8).
Remove the Seeger ring Ø55 (pos. , Fig. 9) and the bearing
Fig. 5
support ring (pos. , Fig. 10) from the pinion
Fig. 6
Fig. 7
32
Fig. 8
Fig. 9
Fig. 10