GE G60 Manual De Instrucciones página 586

Tabla de contenido

Publicidad

B.4 MAPA DE MEMORIA
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 21 de 60)
DIR
NOMBRE DE REGISTRO
5C50
...Repetido para Neutral Instantaneous Overcurrent 6
5C60
...Repetido para Neutral Instantaneous Overcurrent 7
5C70
...Repetido para Neutral Instantaneous Overcurrent 8
5C80
...Repetido para Neutral Instantaneous Overcurrent 9
5C90
...Repetido para Neutral Instantaneous Overcurrent 10
B
5CA0
...Repetido para Neutral Instantaneous Overcurrent 11
5CB0
...Repetido para Neutral Instantaneous Overcurrent 12
Ground Time Overcurrent (configuración agrupada de lectura/escritura) (6 módulos)
5D00
Ground Time Overcurrent 1 Function
5D01
Ground Time Overcurrent 1 Signal Source
5D02
Ground Time Overcurrent 1 Input
5D03
Ground Time Overcurrent 1 Pickup
5D04
Ground Time Overcurrent 1 Curve
5D05
Ground Time Overcurrent 1 Multiplier
5D06
Ground Time Overcurrent 1 Reset
5D07
Ground Time Overcurrent 1 Block
5D08
Ground Time Overcurrent 1 Target
5D09
Ground Time Overcurrent 1 Events
5D0A
Reservado (6 elementos)
5D10
...Repetido para Ground Time Overcurrent 2
5D20
...Repetido para Ground Time Overcurrent 3
5D30
...Repetido para Ground Time Overcurrent 4
5D40
...Repetido para Ground Time Overcurrent 5
5D50
...Repetido para Ground Time Overcurrent 6
Ground Instantaneous Overcurrent (configuración agrupada de lectura/escritura) (12 módulos)
5E00
Ground Instantaneous Overcurrent 1 Signal Source
5E01
Ground Instantaneous Overcurrent 1 Function
5E02
Ground Instantaneous Overcurrent 1 Pickup
5E03
Ground Instantaneous Overcurrent 1 Delay
5E04
Ground Instantaneous Overcurrent 1 Reset Delay
5E05
Ground Instantaneous Overcurrent 1 Block
5E06
Ground Instantaneous Overcurrent 1 Target
5E07
Ground Instantaneous Overcurrent 1 Events
5E08
Reservado (8 elementos)
5E10
...Repetido para Ground Instantaneous Overcurrent 2
5E20
...Repetido para Ground Instantaneous Overcurrent 3
5E30
...Repetido para Ground Instantaneous Overcurrent 4
5E40
...Repetido para Ground Instantaneous Overcurrent 5
5E50
...Repetido para Ground Instantaneous Overcurrent 6
5E60
...Repetido para Ground Instantaneous Overcurrent 7
5E70
...Repetido para Ground Instantaneous Overcurrent 8
5E80
...Repetido para Ground Instantaneous Overcurrent 9
5E90
...Repetido para Ground Instantaneous Overcurrent 10
5EA0
...Repetido para Ground Instantaneous Overcurrent 11
5EB0
...Repetido para Ground Instantaneous Overcurrent 12
Frequency Out-Of-Band Accumulation (configuración de lectura/escritura)
5F40
Frequency Out-Of-Band Accumulation Block
5F41
Frequency Out-Of-Band Accumulation Events
5F42
Frequency Out-Of-Band Accumulator 1 Function
5F43
Frequency Out-Of-Band Accumulator 2 Function
5F44
Frequency Out-Of-Band Accumulator 3 Function
5F45
Frequency Out-Of-Band Accumulator 4 Function
5F46
Frequency Out-Of-Band Accumulator 5 Function
B-30
RANGO
0 a 1
0 a 5
0 a 1
0 a 30
0 a 16
0 a 600
0 a 1
0 a 65535
0 a 2
0 a 1
0 a 1
0 a 5
0 a 1
0 a 30
0 a 600
0 a 600
0 a 65535
0 a 2
0 a 1
0 a 1
0 a 65535
0 a 1
0 a 1
0 a 1
0 a 1
0 a 1
0 a 1
Sistema de protección de generador G60
UNIDADES
PASO
FORMATO
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
---
0.01
F001
---
1
F104
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
---
1
F102
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F300
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
APÉNDICE B
PREDETERMINADO
0 (Desactivado)
0 (SRC 1)
0 (fasor)
1000
0 (IEEE Mod Inv)
100
0 (instantáneo)
0
0 (restablecimiento
automático)
0 (Desactivado)
0
0 (SRC 1)
0 (Desactivado)
1000
0
0
0
0 (restablecimiento
automático)
0 (Desactivado)
0
0
0 (Desactivado)
0 (Desactivado)
0 (Desactivado)
0 (Desactivado)
0 (Desactivado)
0 (Desactivado)
GE Multilin

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido