GE G60 Manual De Instrucciones página 588

Tabla de contenido

Publicidad

B.4 MAPA DE MEMORIA
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 23 de 60)
DIR
NOMBRE DE REGISTRO
6474
Stator Differential Break 1
6475
Stator Differential Break 2
6476
Stator Differential Block
6477
Stator Differential Targets
B
6478
Stator Differential Events
6479
Stator Differential Line End Source
647A
Stator Differential Neutral End Source
Negative Sequence Overvoltage (configuración agrupada de lectura/escritura)
64A0
Negative Sequence Overvoltage Function
64A1
Negative Sequence Overvoltage Source
64A2
Negative Sequence Overvoltage Pickup
64A3
Negative Sequence Overvoltage Pickup Delay
64A4
Negative Sequence Overvoltage Reset Delay
64A5
Negative Sequence Overvoltage Block
64A6
Negative Sequence Overvoltage Target
64A7
Negative Sequence Overvoltage Events
Overfrequency (configuración de lectura/escritura) (4 módulos)
64D0
Overfrequency 1 Function
64D1
Overfrequency 1 Block
64D2
Overfrequency 1 Source
64D3
Overfrequency 1 Pickup
64D4
Overfrequency 1 Pickup Delay
64D5
Overfrequency 1 Reset Delay
64D6
Overfrequency 1 Target
64D7
Overfrequency 1 Events
64D8
Reservado (4 elementos)
64DC
...Repetido para Overfrequency 2
64E8
...Repetido para Overfrequency 3
64F4
...Repetido para Overfrequency 4
Power Swing Detect (configuración agrupada de lectura/escritura)
65C0
Power Swing Detect Function
65C1
Power Swing Detect Source
65C2
Power Swing Detect Mode
65C3
Power Swing Detect Supervision
65C4
Power Swing Detect Forward Reach
65C5
Power Swing Detect Forward RCA
65C6
Power Swing Detect Reverse Reach
65C7
Power Swing Detect Reverse RCA
65C8
Power Swing Detect Outer Limit Angle
65C9
Power Swing Detect Middle Limit Angle
65CA
Power Swing Detect Inner Limit Angle
65CB
Power Swing Detect Delay 1 Pickup
65CC
Power Swing Detect Delay 1 Reset
65CD
Power Swing Detect Delay 2 Pickup
65CE
Power Swing Detect Delay 3 Pickup
65CF
Power Swing Detect Delay 4 Pickup
65D0
Power Swing Detect Seal In Delay
65D1
Power Swing Detect Trip Mode
65D2
Power Swing Detect Block
65D3
Power Swing Detect Target
65D4
Power Swing Detect Event
B-32
RANGO
1 a 1.5
1.5 to 30
0 a 65535
0 a 2
0 a 1
0 a 5
0 a 5
0 a 1
0 a 5
0 a 1.25
0 a 600
0 a 600
0 a 65535
0 a 2
0 a 1
0 a 1
0 a 65535
0 a 5
20 to 65
0 a 65.535
0 a 65.535
0 a 2
0 a 1
0 a 1
0 a 1
0 a 5
0 a 1
0.05 a 30
0.1 a 500
40 a 90
0.1 a 500
40 a 90
40 a 140
40 a 140
40 a 140
0 a 65.535
0 a 65.535
0 a 65.535
0 a 65.535
0 a 65.535
0 a 65.535
0 a 1
0 a 65535
0 a 2
0 a 1
Sistema de protección de generador G60
UNIDADES
PASO
FORMATO
pu
0.01
F001
pu
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F167
---
1
F167
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F167
Hz
0.01
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F513
pu
0.001
F001
ohms
0.01
F001
grados
1
F001
ohms
0.01
F001
grados
1
F001
grados
1
F001
grados
1
F001
grados
1
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F514
---
1
F300
---
1
F109
---
1
F102
APÉNDICE B
PREDETERMINADO
115
800
0
0 (restablecimiento
automático)
0 (Desactivado)
0 (SRC 1)
0 (SRC 1)
0 (Desactivado)
0 (SRC 1)
300
50
50
0
0 (restablecimiento
automático)
0 (Desactivado)
0 (Desactivado)
0
0 (SRC 1)
6050
500
500
0 (restablecimiento
automático)
0 (Desactivado)
0
0 (Desactivado)
0 (SRC 1)
0 (Two Step)
600
5000
75
5000
75
120
90
60
30
50
17
9
17
400
0 (Delayed)
0
0 (restablecimiento
automático)
0 (Desactivado)
GE Multilin

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido