GE G60 Manual De Instrucciones página 610

Tabla de contenido

Publicidad

B.4 MAPA DE MEMORIA
Tabla B–9: MAPA DE MEMORIA DE MODBUS (Hoja 45 de 60)
DIR
NOMBRE DE REGISTRO
AD37
IEC 61850 Logical Node XCBRx Name Prefix
(2 elementos)
AD3D
IEC 61850 Logical Node PTRCx Name Prefix
(2 elementos)
AD43
IEC 61850 Logical Node PDIFx Name Prefix
(4 elementos)
B
AD4F
IEC 61850 Logical Node MMXNx Name Prefix
(37 elementos)
IEC 61850 GOOSE/GSSE Configuration (configuración de lectura/escritura)
B01C
Default GOOSE/GSSE Update Time
B01D
IEC 61850 GSSE Function (GsEna)
B013
IEC 61850 GSSE ID
B03F
IEC 61850 GOOSE Function (GoEna)
B040
IEC 61850 GSSE Destination MAC Address
B043
IEC 61850 Standard GOOSE ID
B064
IEC 61850 Standard GOOSE Destination MAC Address
B067
IEC 61850 GOOSE VLAN Transmit Priority
B068
IEC 61850 GOOSE VLAN ID
B069
IEC 61850 GOOSE ETYPE APPID
B06A
Reservado (2 elementos)
IEC 61850 Server Configuration (configuración/comandos de lectura/escritura)
B06C
TCP Port Number for the IEC 61850 / MMS Protocol
B06D
IEC 61850 Logical Device Name
B07D
IEC 61850 Logical Device Instance
B08D
IEC 61850 LPHD Location
B0B5
Include non-IEC 61850 Data
B06B
IEC 61850 Server Data Scanning Function
B0B7
Reservado (15 elementos)
IEC 61850 MMXU Deadbands (configuración de lectura/escritura) (6 módulos)
B0C0
IEC 61850 MMXU TotW Deadband 1
B0C2
IEC 61850 MMXU TotVAr Deadband 1
B0C4
IEC 61850 MMXU TotVA Deadband 1
B0C6
IEC 61850 MMXU TotPF Deadband 1
B0C8
IEC 61850 MMXU Hz Deadband 1
B0CA
IEC 61850 MMXU PPV.phsAB Deadband 1
B0CC
IEC 61850 MMXU PPV.phsBC Deadband 1
B0CE
IEC 61850 MMXU PPV.phsCA Deadband 1
B0D0
IEC 61850 MMXU PhV.phsADeadband 1
B0D2
IEC 61850 MMXU PhV.phsB Deadband 1
B0D4
IEC 61850 MMXU PhV.phsC Deadband 1
B0D6
IEC 61850 MMXU A.phsA Deadband 1
B0D8
IEC 61850 MMXU A.phsB Deadband 1
B0DA
IEC 61850 MMXU A.phsC Deadband 1
B0DC
IEC 61850 MMXU A.neut Deadband 1
B0DE
IEC 61850 MMXU W.phsA Deadband 1
B0E0
IEC 61850 MMXU W.phsB Deadband 1
B0E2
IEC 61850 MMXU W.phsC Deadband 1
B0E4
IEC 61850 MMXU VAr.phsA Deadband 1
B0E6
IEC 61850 MMXU VAr.phsB Deadband 1
B0E8
IEC 61850 MMXU VAr.phsC Deadband 1
B0EA
IEC 61850 MMXU VA.phsA Deadband 1
B0EC
IEC 61850 MMXU VA.phsB Deadband 1
B0EE
IEC 61850 MMXU VA.phsC Deadband 1
B0F0
IEC 61850 MMXU PF.phsA Deadband 1
B0F2
IEC 61850 MMXU PF.phsB Deadband 1
B-54
RANGO
0 a 65534
0 a 65534
0 a 65534
0 a 65534
1 to 60
0 a 1
---
0 a 1
---
---
---
0 a 7
0 a 4095
0 a 16383
0 a 1
1 a 65535
---
---
---
0 a 1
0 a 1
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
0.001 a 100
Sistema de protección de generador G60
UNIDADES
PASO
FORMATO
---
1
F206
---
1
F206
---
1
F206
---
1
F206
s
1
F001
---
1
F102
---
---
F209
---
1
F102
---
---
F072
---
---
F209
---
---
F072
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F213
---
---
F213
---
---
F204
---
1
F102
---
1
F102
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
APÉNDICE B
PREDETERMINADO
(None)
(None)
(None)
(None)
60
1 (Enabled)
"GSSEOut"
0 (Desactivado)
0
"GOOSEOut"
0
4
0
0
0
102
"IECName"
"LDInst"
"Location"
0 (Desactivado)
0 (Desactivado)
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
10000
GE Multilin