SubDrive/MonoDrive Connect

Drive Display

Drive Running

When the SubDrive/MonoDrive unit is controlling the motor and pump, the display will be
illuminated and the following information will be shown on the display:
System pressure (in PSI) when using an analog pressure transducer. When
displaying system pressure, the display will include a "P" suffix to the numerical
pressure reading to distinguish it from motor speed. The "P" will steadily flash on
and off when the drive is running.
Motor/pump speed (in Hz) when using the standard pressure sensor.

System Idle

When the SubDrive/MonoDrive unit is powered on and idle (not pumping water), the display
will be illuminated and the following will be shown on the display:
System pressure (in PSI) with the "P" on steady (not flashing) when using an analog
pressure transducer - "- - -" when using the standard pressure sensor.

Fault Detected

When a fault condition is detected in the system, the drive display will illuminate red and
the fault code will be displayed. All fault codes begin with "F" and followed by a one- or
two-digit number. Consult the Diagnostic Fault Codes table in the back of this manual for
more information.

Location of Drive

The SubDrive/MonoDrive controller is intended for operation in ambient temperatures from
-13 °F to 122 °F (-25 °C to 50 °C) at 208/230 VAC input. The following recommendations
will help in selection of the proper location of the controller:
A tank tee is recommended for mounting the tank, analog pressure transducer,
pressure gauge, and pressure relief valve. If a tank tee is not used, the pressure
transducer or pressure sensor should be located within 6 feet (1.8 meters) of
the pressure tank to minimize pressure fluctuations. There should be no elbows
between the tank and pressure transducer or pressure sensor.
The unit should be mounted on a sturdy supporting structure such as a wall or
supporting post. Please take into account the weight of the unit.
The electronics inside the SubDrive/MonoDrive are air-cooled. As a result, there
should be at least 6 inches (15.24 cm) of clearance on each side and below the unit
to allow room for air flow.
The mounting location should have access to 208/230 VAC electrical supply and to
the submersible motor wiring. To avoid possible interference with other appliances,
please refer to the Wire Routing section of this manual and observe all precautions
regarding power cable routing.
The unit should not be installed in corrosive environments.
10