SubDrive/MonoDrive Connect

Drive Wiring

s
WARNING
!
Serious or fatal electrical shock may result from failure to connect the motor, the SubDrive
MonoDrive, metal plumbing, and all other metal near the motor or cable to the power supply
ground terminal using wire no smaller than motor cable wires. To reduce risk of electrical
shock, disconnect power before working on or around the water system. Do not use motor in
swimming areas.
NOTE: Ensure that the system is properly grounded all the way to the service entrance
panel. Improper grounding may result in the loss of voltage surge protection and
interference filtering.
1. Verify that the power has been shut off at the main breaker.
2. Verify that the dedicated branch circuit for the SubDrive/MonoDrive is equipped with a
properly-sized circuit breaker. (See Table 1, pg. 15 for minimum breaker size.)
3. Use appropriate strain relief or conduit connectors. See below for conduit hole and
knockout sizes.
22,2
[0.88]
110.7 [4.36]
MD/MDXT/SD15
SD20/SD30
119.1 [4.69]
SD50
4. Remove the SubDrive/MonoDrive lid.
5. Feed the motor leads through the
opening on the bottom right side of the
unit and connect them to the terminal
block positions marked
Ground Wire), Red, Yellow and Black.
Tighten terminals to 15 in-lbs (1.7 Nm).
24
All manuals and user guides at all-guides.com
22,2
HOLE
[
0.88
]
28.6 KNOCKOUT
[1.13]
KNOCKOUT
97,7
[3.85]
47,7
[1.88]
33,6
[1.32]
40,3
[1.59]
82,3
[3.24]
MD/MDXT/SD15/SD20/SD30
(Green
12,7
HOLE
[0.5]
198.3 [7.81]
205.3 [8.08]
SD50
28,6 HOLE
[1.13]
34.9 KNOCKOUT
[1.37]
97,7
[3.85]