Specifications - Monodrive/Monodrivext - Franklin Electric MonoDrive Connect N3R Manual Del Propietário

Ocultar thumbs Ver también para MonoDrive Connect N3R:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Specifications – MonoDrive/MonoDriveXT
NEMA 3R
Model No.
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Factor
Power Source
Power (idle)*
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Output to Motor
Frequency Range
Current (max)
Wire Gauge Size(s)
Factory Preset
Pressure Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions
(A)
Relative Humidity
Controller Size
(B)
NEMA 3R
(approximate)
Pump (60 Hz)
For Use With
FE Motor
Notes:
(A) Operating temperature is specified at full output power when installed as described in Location of Drive on pg. 10-14.
(B) Refer to pg. 23-26 for detailed Drive Mounting.
* Idle power is defined as input power used by the drive when the drive is not running the motor, the drive fan is off,
and no communication is active. Idle power is increased by 1 W if Wi-Fi is on.
All manuals and user guides at all-guides.com
MonoDrive
5870205003C
208/230 +/- 10% VAC
Single-Phase
60/50 Hz
11A
~ 0.95
4 W
2.5 kW
See Table 1, pg. 18. Consult Federal, State, and Local codes for branch
circuit installations
Variable based on frequency
Single-Phase, (3-Wire)
30-63 Hz
10.4 A
See Table 2, pg. 19 for wire sizing
50 psi (3.4 bar)
Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
-13 °F to 122 °F (-25 °C to 50 °C)
20-95%, non-condensing
9-3/4" x 16-3/4" x 5-1/4" : 20 lbs
(25 x 42.5 x 13 cm) : (9 kg)
0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor
214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
SubDrive/MonoDrive Connect
MonoDriveXT
5870205203C
208/230 +/- 10% VAC
Single-Phase
60/50 Hz
16A
~ 0.95
5 W
4.2 kW
See Table 1, pg. 18. Consult Federal, State, and Local codes for branch circuit
installations
Variable based on frequency
Single-Phase, (3-Wire)
30-63 Hz
13.2 A
See Table 2, pg. 19 for wire sizing
50 psi (3.4 bar)
Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
-13 °F to 122 °F (-25 °C to 50 °C)
20-95%, non-condensing
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motor
214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
37

Publicidad

Tabla de contenido
loading

Tabla de contenido