Underload Sensitivity; Steady Flow Selection - Franklin Electric MonoDrive Connect N3R Manual Del Propietário

Ocultar thumbs Ver también para MonoDrive Connect N3R:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

R24
UB
R106
D4
R57
USB
R39
R58
P2
R23
C29
R21 R34 R35
R56 R66
1
D8
ON
C22
C23
1 2 3 4 5 6 7 8
SW1
BT1
+
Underload Sensitivity: Shallow Set
If the pump is installed in an extremely shallow (i.e. artesian) well and the system continues
to trip, then the Underload Potentiometer (Pot) will need to be adjusted counter-clockwise
to a lower sensitivity setting. Check the Underload trip level and repeat as necessary.
Underload Sensitivity: Deep Set
In cases where the pump is set very deep, run the system at open discharge to pump the
well down and observe carefully that an Underload is detected properly. If the system does
not trip as it should, then the Underload Pot will need to be adjusted clockwise to a higher
sensitivity setting.
If necessary to adjust the Underload Sensitivity, remove power and allow the controller
to discharge. Wait 5 minutes to allow internal voltage to dissipate, locate the Underload
Sensitivity knob, and make necessary adjustments.
Steady Flow Selection (DIP SW1 - Position 4)
The SubDrive/MonoDrive controller is configured at the factory to ensure quick response to
maintain constant pressure. In rare cases (as with a water line tap before the pressure tank),
the controller may need to be adjusted to offer better control.
If the controller is used on a system that has a water line tapped before the pressure tank
and close to the well head or where audible speed variations of the PMA can be heard
through the pipes, adjusting the pressure control response time may be necessary. After
enabling this feature, the installer should check flow and pressure changes for possible
overshoot. A larger pressure tank and/or wider margin between regulation and pressure
relief valve pressure may be required as the Steady Flow feature reduces the controller's
reaction time to sudden changes in flow.
If it is necessary to adjust the pressure control, remove power and allow the controller
to discharge. Wait 5 minutes to allow internal voltage to dissipate, locate the DIP switch
marked "SW1". Move DIP SW1 Position 4 to "ON" (up) position.
All manuals and user guides at all-guides.com
J1
8 1
6
1
6
ON
1 2 3 4 5 6
1 2 3 4 5 6
SW2
SW3
Q2
R79
Q1
U1
D6
C
R65
D3
C20
C26
J2
R48
R71
C45
R51
C25
C14
C10
C9
R30
SubDrive/MonoDrive Connect

Underload Sensitivity

P3
Potentiometer
UNDERLOAD
R47
D11
R5
PRESSURE
SET POINT
C21
C16
C27
U8
C13
C15
R85
C28
R70
31

Publicidad

Tabla de contenido
loading

Tabla de contenido