Fuse/Circuit Breaker and Wire Sizing

The Listed fuse/Listed circuit breaker size and maximum allowable wire lengths for
connection to the SubDrive/MonoDrive are given in the following tables:
Table 1: Circuit Breaker Sizing and Maximum Input Cable Lengths (in Feet)
Based on a 3% voltage drop
Listed Fuse /
Model Family
Listed Circuit
Breaker Amps
15
MonoDrive C
15
15
SubDrive15 C
15
20
MonoDriveXT C
20
20
SubDrive20 C
20
25
SubDrive30 C
25
40
SubDrive50 C
40
XXXX
Highlighted Numbers denote wire with 194 °F (90 °C) insulation only.
NOTE: Not to be used on a Ground Fault Circuit Interrupter (GFCI). If using an externally regulated generator, verify that the
voltage, Hertz and idle speed are appropriate to supply the drive.
All manuals and user guides at all-guides.com
DO NOT run ground wire separate.
Motor ground wire MUST be bundled with motor wires.
AWG Copper Wire Sizes, 167 °F (75 °C) Insulation Unless Otherwise Noted
Nominal
Input
14
12
Voltage
208
80
125
230
95
150
208
70
110
230
85
135
208
-
85
230
-
105
208
-
-
230
-
85
208
-
-
230
-
-
208
-
-
230
-
-
SubDrive/MonoDrive Connect
10
8
6
4
3
205
315
500
790
980
250
385
615
970
1200
185
280
450
710
880
225
345
550
865
1075
140
220
345
550
680
175
265
425
670
835
115
180
285
450
555
140
220
345
550
680
95
145
235
370
460
115
180
285
455
560
-
-
150
235
295
-
115
185
290
360
Pump
Motor
2
1
1/0
2/0
1290
1635
-
-
1580
2000
-
-
1160
1465
-
-
1415
1795
-
-
895
1135
-
-
1095
1390
-
-
730
925
-
-
895
1130
-
-
605
765
-
-
740
935
-
-
385
490
610
735
470
600
745
895