Franklin Electric MonoDrive Connect N3R Manual Del Propietário página 25

Ocultar thumbs Ver también para MonoDrive Connect N3R:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

s
CAUTION
!
For retrofit application (i.e. MonoDrive), make sure to check integrity of power and motor leads.
This requires measuring the insulation resistance with the suitable megohmmeter.
* See AIM Manual for specifications.
6. Feed the 230 VAC power leads
through the larger opening on the
bottom left side of the SubDrive/
MonoDrive controller and connect
them to the terminals marked L1,
L2, and
. Tighten terminals to
15 in-lbs (1.7 Nm).
7. For analog pressure transducer
or pressure sensor leads, use the
smaller opening on the bottom of
the SubDrive/MonoDrive unit (to the
right of the input power leads).
For Analog Pressure Transducer
NOTE: A 10-foot (3 m) section of
pressure transducer cable is provided with the controller. Other lengths are available. See
Accessories section for ordering information.
a. Locate the terminal block labeled TRANSDUCER (XDCR).
b. Connect the RED lead of the pressure transducer cable to the +24 terminal of the
XDCR terminal block.
c. Connect the BLACK lead of the pressure transducer cable to the - terminal.
d. Connect the bare shield lead of the pressure transducer cable to the S terminal
(where applicable).
e. Tighten terminals to 5 in-lbs (0.6 Nm) with a small screwdriver (provided).
f.
Torque the fitting as shown in the figure to the right.
For SubDrive Pressure Sensor
s
CAUTION
!
When increasing the pressure, do not exceed the mechanical stop on the pressure sensor
or 80 psi (5.5 bar). The pressure sensor may be damaged.
a. Locate the terminal block labeled PRESSURE SENSOR (PS).
b. Connect the red and black leads (interchangeable) of the pressure sensor cable to
the terminals of the PS terminal block on the Pressure Input Board.
c. Tighten terminals to 5 in-lbs (0.6 Nm) with a small screwdriver (provided).
d. Torque the fitting as shown in the figure to the right.
All manuals and user guides at all-guides.com
Suitable for use on a circuit
capable of delivering not more
than 5000 rms symmetrical
amperes, 250 V maximum. Use 75
ºC CU wire rate 300 V min.
Convenable pour utilisation sur un
circuit capable de livrer pas plus
de 5000 ampères symétriques
pae, 250 V maximum. Utilisez un fil
nominale classifier 75 °C CU /
300 V min
Adecuado para utilizarse en un
circuito capaz de entregar no más
de 5.000 amperes RMS
simétricos, 250 V como máximo.
Use alambre de 75 °C CU con una
clasificación mínima de 300 V.
Tighten terminals to 15 in-lbs.
Serrer les terminaux à 15 po-lb
Apriete las terminales a
15 pulgadas-libra.
SubDrive/MonoDrive Connect
C2
R99
R104
C50
R100
C33
D15
R101
TP82
R103
C4
R98
TP80
R105
C49
D16
C7
R97
P1
D10
IMAG
RoHS
94V-0
BD02
Compliant
38 15
A
_
WS
A
B
+24
|
+
|
ALTERNATOR
WET SENSOR
J6
J1
J5
A1
PS
XDCR
+24 _
L1
L2
IN
PRESSURE
AUX INPUT
SENSOR
TRANSDUCER
WARNING – Retain Owner's Manual.
Installation and operation of this equipment
requires detailed instructions as provided in
the Owner's Manual.
AVERTISSEMENT - Conserver le manuel du
propriétaire. L'installation et le
fonctionnement de cet équipement
nécessite des instructions détaillées fournies
dans le manuel du propriétaire.
ADVERTENCIA – Conserve el Manual de
Usuario. Para la apropiada instalación y
R69
operación de este producto, se requiere
seguir detalladas instrucciones contenidas
R20
U10
en el Manual del Usuario.
R88
C11
R91
TP71
R93
R95
Use 75 ºC CU wire rated 600 V min
J3
J4
R96
TP76
Utilisez un fil nominale classifier
TP78
75 °C CU / 600 V min
Use alambre de 75 °C CU con
una clasificación mínima de
600 V.
Tighten terminals to 15 in-lbs.
C2 C1
Serrer les terminaux à 15 po-lb
Apriete las terminales a
15 pulgadas-libra.
R1
R2
S
NC COM NO
NC COM NO
RED
YEL
BLK
ALARM RELAY
RUN RELAY
25

Publicidad

Tabla de contenido
loading

Tabla de contenido