All electrical connections have been correctly made as in Figures 6-9.
Nederman start and control units have the terminals connected, and in
some cases jumped connections. Verify against the connecting diagrams.
The pilot signal cable from all valves is linked to the start and control unit
on units with automatic start/stop.
Anti surge control: The current transformer is connected to the relay box.
8.2
Initial start-up
8.2.1
Checking the direction of rotation
At initial start-up, check the direction of rotation by doing the following:
1.
Start the unit.
2.
Compare the direction of the motor rotation with the arrow on the motor.
If the direction of the motor and the arrow are the same, allow the starting
procedure to continue.
If the direction of the motor is different from the direction of the arrow,
change the direction of the motor by doing the following:
1)
2)
3)
4)
8.2.2
Checking the Y/D time setting
NOTE!
be adjusted.
Switching to D mode before the motor has reached full speed can damage the
start and control unit. This is particularly important when automatic start and
stop is installed. Too long in Y mode results in an unnecessary delay before the
unit delivers full vacuum.
At initial start-up check the Y/D time setting by doing the following:
Make sure the motor sound is constant and high pitched, indicating full
motor effect, before the motor switches to D mode.
8.2.3
Initial start-up with pilot signal cable
For units with pilot signal cable also ensure the following at initial start-up:
The unit only starts directly when one of the following occurs:
The unit shuts down when the time set on the timer relay has elapsed after
the valve is closed (up to 30 minutes).
26
Stop the unit.
Disconnect power.
Open the start and control unit
Switch two of the incoming phase conductors.
The Y/D time setting is factory preset and does not normally need to
A valve is opened at a work site, causing the micro switch to close.
The test start button is pressed on the start and control unit (if
available).