9.5
Special features during the motor calibration
INFO
Calibrate the weld torch in accordance with the ORBIMAT operating instructions.
A calibration of the motors of the individual weld torches is possible.
When starting this function the weld torch connected to the active output channel is calibrated.
If two weld torches of different types are connected to the ORBITWIN SW, no special points have to be observed since the
software of the power supply can save an own, current speed, determined from the motor calibration for each torch type.
If two weld torches of the same type are connected to the ORBITWIN SW, the possible deviation which was determined
during the motor calibration is also considered during the operation of the second weld torch since the power supply can only
store one current speed value per torch type. In this case ensure that the rotary speeds of the weld torches do not differ substan-
tially from each other.
If the deviation is too large, this error has to be eliminated by setting the compensation potentiometer in the weld torch corre-
spondingly.