Descargar Imprimir esta página

Orbitalum ORBITWIN SW Traduccion Del Manual De Instrucciones Originale página 50

Unidad de conmutación

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 99
eNGLISH
Maintenance and troubleshooting
10. MAINTeNANCe AND TROUBLeSHOOTING
10.1
Instructions for care
X Do not use lubricants or sliding agents.
X Ensure that no dirt particles, small parts or liquids enter the interior of the ORBITWIN.
X If the surfaces are soiled, use only residue-free cleaning agents for cleaning.
10.2
Maintenance and care
The following instructions for care depend, if not stated otherwise, strongly on the usage of the switching device.
Shorter cleaning intervals influence the equipment service life positively.
INTeRVAL
Daily
Monthly
Annually
10.3
Troubleshooting
PROBLeM
Output channel cannot be
switched over
No permanent gas flow
10.4
Servicing/Customer service
The following data are required to order spare parts:
• Device type: ORBITWIN SW
• Device No.: See type plate
X For ordering spare parts, see the separate spare part list.
X Contact your local branch directly in order to eliminate problematic situations.
50
ORBITALUM TOOLS GmbH D-78224 Singen www.orbitalum.com
ACTIVITY
X Check the switching device, connection hoses and cables, power cables and mains plugs for
damage.
X Clean the switching device fully from the outside.
X Have the BGV-A3 test carried out by Orbitalum or through another certified body.
POSSIBLe CAUSe
No input voltage.
Signal cable interruption.
Permanent gas not switched on.
Gas hose not connected.
Gas cylinder closed.
Flow meter closed.
ReMeDY
X Power supply switched on?
X Check the power line.
X Check the control cable connection of ORBIT-
WIN to the power supply and ORBITWIN to
the weld torch.
X Press the "Permanent gas" pressure switch.
X Check the gas input socket at the device rear.
X Check the gas cylinder valve.
X Check the flow meter valve.
[REV. 20230213] OW_ORBITWIN_SW_BA_853060201_01__INH-02_EN
ORBITWIN SW

Publicidad

loading

Productos relacionados para Orbitalum ORBITWIN SW

Este manual también es adecuado para:

853 000 001