2. INSTALLATION
2.1. PLATE DATA
•
Check that the data on the plate and the electric
power supply characteristics correspond (V, kW, Hz,
no. of phases and available power).
•
The plate with the characteristics of the unit is found
on the right side of the conservation unit (fig.2) and
under the control panel.
Preparation of machinery rooms for the condensing
units must comply with fire prevention standards in the
country of installation. Contact the local fire department
for instructions.
Also keep in mind that the intervention of safety
valves or fuse plugs in the refrigerating circuit will result
in the immediate discharge in the environment of all the
coolant used. Please arrange for suitable disposal
methods and emergency measures as shown in the
coolant technical data sheet (
Climatic classes:
T class tropical (ambient temperature between 18°C
•
a n d 4 3 ° C ) i n a c c o r d a n c e w i t h s t a n d a r d C E I E N
60335-1
5 ( t e m p e r a t u r e 4 0 ° C , r e l a t i v e h u m i d i t y 4 0 % ) i n
•
accordance with standard UNI EN ISO 23953-2
2.2. POSITIONING
•
The machine must be installed and tested by fully
respecting the accident-prevention standards, traditi-
onal precautions and the laws in force.
The installer must check for any fire-prevention rules
•
(consult the local fire department for instructions).
Place the machine in its location.
•
Permanently level the appliance by means of the
•
adjustable feet. Use special hoisting apparatus for
the heaviest machines (fig. 3).
If the cells are not levelled, their proper functioning and
•
the drainage of condensation may be jeopardized.
Avoid (Fig.4):
Places exposed to direct sunlight
•
Closed locations that are hot and have poor air circu-
•
lation (
see table 2).
Avoid installing the machine near any source of heat.
•
All manuals and user guides at all-guides.com
see par. 2.12).
6
31010
CORBANESE (TV)
ITALY
Mod.
y/n
V
Ph
A
Compressor
HERMETIC
Refrigerant
R404
Charge
Design pressure (Low)
Design pressure (High)
Class
Volume
Rated Load
IP
PED Code
Fig. 2
Fig. 3
Fig. 4
Model
Serial number
mm/yy/progres.
Hz
Kw
Frequency
Power
KPa
Phase
KPa
Volt
Power input