Phase
5
Manual defrosting
Access parameter programming by following the
instructions in Paragraph 3.6 "PARAMETER
PROGRAMMING".
Select manual 4, manual defrosting.
6
Sanification
Access parameter programming following the
instructions in Paragraph 3.6
"PARAMETER PROGRAMMING"
Select "Yes" parameter 1-9 "Sanigen"
3.4. SHUTDOWN MODES
In case of emergency, to shut down the machine, press
the ON/OFF key and cut off the power supply from the
main panel (Fig.21 ).
3.5. SUGGESTIONS FOR USE
Before putting the machine in operation, it is necessary
to carefully clean the inside of the cell (
3.5.1. Pre-cooling
Before using the conservation unit for the first time, or
after a long period of disuse, pre-cool the cell by running
the machine empty until the set working temperature is
reached.
To obtain good performance from the machine
without altering foods, we suggest the following:
do not place hot foods or liquids in the cell without a
cover.
arrange products so as to favour cold air circulation
throughout the cell.
avoid prolonged and frequent door opening.
3.5.2. Loading the machine
Take care that there is enough space between pans,
so as to allow sufficient air circulation.
If the machine is not fully loaded, spread the pans
and the load evenly throughout the entire height, avoiding
concentrations.
When using the CP in positive mode (15÷0°C), run
the conservation unit empty for at least four hours so as to
work at the desired relative humidity.
All manuals and user guides at all-guides.com