3.4 ELECTRICAL CONNECTION
The electrical connection must ONLY be made by specialised
technicians. The electrical protection of the electrical connection
upstream of the appliance must comply with the standards in force.
CAUTION
Make sure that the voltage (V) and frequency (Hz) indicated
on the nameplate inside the appliances correspond to
those available at the installation site.
Any changes that may be necessary to the electrical system in order
to install the hood must only be carried out by competent persons.
After installation, insulated and current-carrying parts must be
protected against contact.
CAUTION
If the electrical connection is made incorrectly or not in
accordance with standards, parts of the appliance may
become damaged and the warranty shall not cover this.
CAUTION
Disconnect the appliance from the mains before any work
is carried out (Fig. 1- Fig. 2 WARNINGS chapter).
These appliances must be connected to an earthed system.
The appliance must be connected to the mains power system,
interposing an omnipolar switch that ensures mains disconnection,
with a contact opening distance that allows complete disconnection
under the conditions of overvoltage category III in accordance with
the installation rules (Fig. 22).
12
Fig. 22
The earth connection (yellow-green cable) must not be
interrupted under any circumstances.
The power cable must be long enough to connect the appliance
recessed in the cabinet to the mains supply. If the power cable is
damaged, it must be replaced in order to prevent any risks.
If the mains cable is damaged, it must be replaced by the
manufacturer or its technical customer service or a similarly
qualified person in order to prevent any risks.
CAUTION
We cannot be held liable for any accidents resulting from
an incorrect connection or which may result from use of an
appliance which has not been connected to earth or which
has been fitted with a defective earth connection.
Protection against live parts must be ensured after installation.
Connection to the mains must be made using an earthed plug or
an omnipolar circuit-breaking device with a contact opening of at
least 3 mm.
The power cable must be positioned so that it does not touch hot
parts of the hob or anything else.
Use a power cable with a conductor cross-section suitable for
power up to 7360 Watts to connect the appliance to the mains.
Note: the product is equipped with a Power Limitation function
that allows you to set a maximum absorption threshold (Kw). This
setting must be made when the product is connected to the mains or
when the mains is reconnected (within 2 minutes). Size the electrical
system protection according to the selected Power Limitation level.
See this manual in the Operation section for the Power Limitation
setting sequence.
At no point should the cable reach a temperature of 50°C above
the ambient temperature.
The appliance is intended to be permanently connected to the
mains.
CAUTION
Comply with the following connection diagram (Fig. 23):