WARNING: Those authorised to car-
ry out this operation must have experience
acquired and certified in the specific sector,
must make the connection to the proper stan-
dards, and must comply with all the relevant
regulations and legislation . Once the connec-
tion has been made, before the appliance is
put into operation a general check must be
made to ensure there are no gas leaks .
To make the connection, connect the mains
line to the appliance's connection pipe, fitting
a shut-off tap (A), to allow the gas supply to be
cut off when necessary .
WARNING: The tap (A), not supplied
with the appliance, must be installed in an
easily accessible position and its status (on
or off) must be obvious at a glance .
IMPORTANT: The gas supply pipe
must comply with the national requirements
in force and must be periodically examined
and replaced if necessary .
IMPORTANT: Make the connection in
compliance with the relevant legal require-
ments, using appropriate and recommended
materials .
Position the appliance un-
1)
derneath the hood (A) (see
diagram) .
IMPORTANT: The gas
supply tap (A) must open au-
tomatically when the fan
of the extraction system is
switched on .
12
GAS CONNECTION
CONNECTION OF FUME EXHAUST VENT
A
HANDLING AND INSTALLATION
A
HAZARD: Do not connect the appli-
ance to the gas distribution system contain-
ing carbon monoxide or other toxic compo-
nents .
WARNING: The gas feed pipe must
not be longer than 2 metres .
Connecting to a fan extractor hood
To carry out this operation, proceed as follows .