HANDLING AND INSTALLATION
NOTE: The connection must be made
by authorised, skilled personnel, in accor-
dance with the relevant legal requirements,
using appropriate and specified materials .
The appliance is supplied with operating
voltage 230V1N 50 Hz ( 60 Hz on request) .
For direct connection to the mains one must
envisage a device that ensures disconnection
from the mains, with a contacts opening dis-
tance that ensures complete disconnection in
the conditions of category III over-tension, in
compliance with the installation rules .
A
Undo the screw (F) to remove the lid (G) .
4)
Connect the circuit-breaker (A) to the termi-
5)
nal board (H) of the appliance, by passing the
power cable through the cable gland (L) of
the appliance as shown in the diagram at the
back of the manual . Use a cable with at least
H05RN-F characteristics .
– Weight: ≥ than H05RN-F type (designation
245 IEC 57)
– Temperature of use: ≥ 80°
Tighten the cable gland (L) .
6)
WARNING: When connecting, take
care to connect the neutral and earth lines .
Replace all when the operation is complete .
7)
3413920_inst_GB
ELECTRICAL CONNECTION
off the mains electricity supply .
Connect the appliance to the mains electricity
supply as follows:
If not already present, install a circuit-breaker
1)
(A)
safety breaker close to the appliance:
Remove the knob (C) .
2)
Undo the screws (D) and remove the control
3)
panel (E) .
C
D
HAZARD: Before doing any work, cut
with overload cutout and residual current
E
D
G
F
H
L
ENGLISH
13