FAULTS
The appliance has been tested before com-
missioning. The information provided below
is intended to help identify and correct any
anomalies and malfunctions which might oc-
cur during use.
Some of these issues may be resolved by the
user, whereas other issues require specifi c
technical knowledge or skill, and therefore
they must be dealt with by qualifi ed staff with
recognised experience acquired in the specifi c
sector of operation.
Issues
Smell of gas
The pilot light does not
light up
The pilot light goes off .
The fl ame is yellow.
Burner control knob is
stiff .
The pilot light of the
oven goes off .
3386390_ut_GB
FAULTS
TROUBLESHOOTING
Causes
Occasional leak because
fl ame has gone off .
The spark ignition devices
are not working.
Air in pipelines due to long
period of downtime.
The thermocouple has not
heated up enough.
The burner is dirty.
Gas control valve fault.
The safety thermostat of the
oven has tripped.
Thermocouple fault.
Oven safety thermostat fault.
NOTE:
For any need, please contact Angelo Po's
agents or headquarters, which can be found
in the contacts section of the website www.
angelopo.com.
Close the gas supply tap and
ventilate the room.
Check that the ignition devices are
in good working order. Light by
hand with a naked light.
NOTE: Contact the af-
ter-sales service.
Make more attempts
to light the fl ame.
Make more attempts
to light the fl ame.
Clean the burner
NOTE: Contact the af-
ter-sales service.
Reset the safety thermostat (see
page 21); if the problem persists,
call the after-sales service.
NOTE: Contact the af-
ter-sales service.
NOTE: Contact the af-
ter-sales service.
ENGLISH