INSTRUCTIONS AND WARNINGS FOR PART REPLACEMENT
NOTE: Read the following section of
the "user instruction manual" carefully be-
fore replacing any part:
– Hazards and safety provisions during instal-
lation and commissioning, adjustments and
part replacement.
WARNING: Before carrying out any
replacement procedure, activate all the
safety devices provided and decide wheth-
er staff at work and those in the vicinity
should be properly informed. In particular,
close the gas supply tap and prevent access
REPLACING THE TOP BURNER NOZZLE (Ø 80 - 4 KW)
To carry out this operation,
proceed as follows.
Close the gas supply tap.
1)
Remove the grid (A).
2)
Extract the burner (B).
3)
Unscrew the nozzle (C)
4)
and replace it with the
one suitable for the type
of gas in use (see table at
the end of the manual).
Replace the burner and
5)
the grid.
REPLACING THE TOP BURNER NOZZLE (Ø 110 - 6.5 KW)
To carry out this operation, proceed as follows.
Close the gas supply tap.
1)
Remove the grid (A).
2)
Extract the burner (B).
3)
Unscrew the nozzle (C)
4)
and replace it with the
one suitable for the
type of gas in use (see
table at the end of the
manual).
Replace the burner and
5)
the grid.
16
PART REPLACEMENT
A
A
to all devices which might cause unexpect-
ed hazards and damage to people's health
and safety if activated. When replacing worn
parts, use original spare parts only.
The manufacturer declines all responsibil-
ity for injury or damage to components re-
sulting from the use of non original parts, or
extraordinary work on the appliance which
may modify the safety requirements with-
out the manufacturer's authorisation.
When ordering components, follow the in-
structions provided in the spare part cata-
logue.