GB
Type of lubrication
Hot engine oil pressure
Oil cooling
Oil change
ATTENZIONE - WARNING
SOSTITUIRE OLIO OGNI 500 ORE
CHANGE OIL EVERY 500 HOURS
IMPORTANT
Engines provided with oil sump with
a maximum capacity of 11.5 kg have
a label on the top of the engine that
shows the oil change interval every 500
hours.
English
Lubrication circuit
-
forced lubrication with rotor pump
The engine oil must have the following characteristics:
- Viscosity grade SAE 10W-40
- Oil quality standard: ACEA E6 + E9 or
- TBN (Total Base Number) ≥ 10mgKOH/g.
- Lubricants recommended for ambient temperatures from -20°C
-
Petronas Urania 5000 LS 10W-40
In case of lower ambient temperatures (down to -30°C) it's al-
lowed to use an engine oil with the above specifications and the
Do not mix oils with different characteristics
bar
bar
-
engine oil sump without balancing masses 300 hours/8.7 kg
engine oil sump with balancing masses 300 hours/7.4 kg
(kg)
engine oil sump without balancing masses 500 hours/11.5 kg
engine oil sump with balancing masses 500 hours/10.7 kg
14
- Full or semi-synthetic.
E8 + E11, API CJ4 / CK4.
(-4°F) to +50°C (+122°F):
or:
Motorex Focus QTM 10W-40
following grade:
SAE 5W-40 or SAE 5W-30.
1.5 at minimum engine speed
4.3 - 6.0 at 2000 engine rpm
Oil/water cooler
R754ISE5
42432106F