TABLE OF OPERATOR WARNING SYSTEM MANAGEMENT CONDITIONS AND
INDUCEMENT SYSTEM ACTIVATION
- The table below summarises the conditions for operator warning system management
GB
and inducement system activation.
TYPE OF
MALFUNCTION
EGR valve blocked
Tampering with the
monitoring system
English
WARNING activation
of DWS warning light
(DWS WARNING
LIGHT
STATUS -
STEADY LIGHT ON)
Improper exhaust gas
recirculation
Improper monitoring
sensor operation
LEVEL 1
Counter for
activation of level 1
(DWS WARNING
LIGHT
STATUS
- FLASHING LIGHT
ON)
after 36 hours from
activation of DWS
warning light steady
ON
after 36 hours from
activation of DWS
warning light steady
ON
32
R754ISE5
LEVEL 2
Counter for activation
of level 2
(DWS WARNING
LIGHT
STATUS -
FLASHING LIGHT ON)
after 100 hours from
activation of DWS
warning light steady ON
after 100 hours from
activation of DWS
warning light steady ON
42432106F