Operation
TESTING AND ADJUSTING THE BIN THERMOSTAT
The bin thermostat stops the ice machine when the bin
is full. It is preset for normal ambient temperatures and
adjustments are usually not required.
The thermostat is functioning correctly if, when three ice
cubes are placed on the thermostat tube for 5 minutes, the
ice machine stops. The ice machine should restart 5 minutes
after the cubes are removed.
If the ice machine stops before the bin is full or runs after the
bin is full, ambient temperatures are probably high or low
and the bin thermostat can be adjusted as follows:
1. To access the thermostat, remove the two screws
attaching the front grill and remove the grill.
2. Turn the thermostat to the left to decrease the level
of ice before automatic shut-off. Turn to the right to
increase the level of ice before automatic shut-off.
3. Reassemble the plastic panel and grill.
22
Cube Weight Adjustment
The cube weight can be increased from the factory setting by
adjusting the finish time.
ADDITIONAL FINISHING TIME CHECK
Press and hold the power button for 5 seconds.
Count the flashes on the Automatic Ice Making light.
The light will flash once for each additional minute of freeze
cycle time.
ADJUSTING FINISHING TIME
Adjust in 1 minute increments and allow the ice machine to
run several freeze/harvest cycles, then inspect the ice cubes.
If a heavier cube weight is desired add another minute of
freeze time and repeat the process.
1. Press and hold the power button.
2. Press and release the clean button once for each
additional minute of freeze cycle time desired.
3. Five minutes is the maximum additional freeze time that
can be added. Pressing the clean button 6 times will
reset the finishing time to zero additional minutes.
Cube weight increases or decreases depending on the
amount of dimple in the cube
Part Number 0000017452 Rev 00 06/22