Descargar Imprimir esta página

Manitowoc UP0050 Manual De Instrucciones página 24

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
In Place De-scaling/Sanitizing Procedure
This procedure allows monthly in place de-scaling of all
surfaces that come in contact with the water system. The
ice machine requires disassembly and de-scaling/sanitizing
a minimum of once every 12 months. The quality of your
potable water supply may require more frequent de-scaling
intervals.
Ice machine Metal Safe De-scaler is used to remove lime
scale and mineral deposits. Ice machine Sanitizer disinfects
and removes algae and slime.
NOTE: All ice must be removed from the bin.
Step 1
Prepare 4 oz (1/2 cup) of undiluted Manitowoc
Ice Machine Metal Safe De-scaler (part number 000000084
only) in a container that will fit easily under the lifted water
shutters. Refer to "Component Identification" on page 19
to identify the water shutters.
Model
UCP0050
Step 2
Press the Clean button. The ice machine will
initiate a 2 minute harvest to remove any remaining ice from
the evaporator.
Step 3
Remove all ice from the bin.
Step 4
Wait 3 minutes until the Clean light flashes, then
add the prepared Metal Safe De-scaler by lifting the water
shutters and pouring directly into the spray area.
Step 5
The ice machine will automatically time out a ten
minute de-scaling cycle, followed by eight rinse cycles, and
stop. The Clean light will turn off to indicate the cycle is
complete. This entire cycle lasts approximately 30 minutes.
Step 6
Prepare 1/2 oz (1 tablespoon) of undiluted
Manitowoc Ice Machine Sanitizer (part number 9405653
only) in a container that will fit into the same area.
Model
UCP0050
24
Amount of Metal Safe De-scaler
000000084
4 ounces (120 ml)
Amount of Sanitizer
9405653
1/2 Ounce (15ml)
Step 7
Press the Clean button. Wait 3 minutes until
the Clean light flashes, then add the prepared Manitowoc
Sanitizer by lifting the water shutters and pouring directly
into the spray area. The ice machine will automatically time
out a ten minute sanitizing cycle, followed by eight rinse
cycles, and stop. The Clean light will turn off to indicate
the sanitizing cycle is complete. This entire cycle lasts
approximately 30 minutes.
NOTE: The ice machine will automatically continue from the
previous point before the cycle was initiated.
A. If the ice machine was in the ice making cycle, the
control board will start ice making again.
B. If the ice machine was in the off cycle, the control
board will turn off.
Step 8
Mix a solution of 1/4 oz. (7.4 ml) of sanitizer and
1/2 gallon (1.9 L) of water. Use a spray bottle, sponge or cloth
to sanitize the bin. Rinsing is not required.
Part Number 0000017452 Rev 00 06/22
Section 4

Publicidad

loading