Current
Voltage
I S5.0 [9566]
V
V
I S5.1
X521.3
Hardware smoothing
S5.1
+
<1>
AI 1
-
X521.4
+/-20 mA
+/-10 V
TM31 AI Inv S_src
p4067[1]
TM31 AI absVal act
p4066[1] (0)
0
1
<1> Differential input!
For an input signal referred to ground, terminal X521.4 must be connected to reference potential M.
Caution:
The voltage between an input (X521.3 or X521.4) and the ground point must not exceed 35 V.
When the load resistor is switched in (S5.1 closed), the voltage between the input terminals must not exceed 15 V.
<2> For p4056 = 2, 3, 5 the units are mA.
For p4056 = 0, 4 the units are V.
1
2
DO: TM31
Terminal Module 31 (TM31) - Analog input 1 (AI 1)
<2>
TM31 AI offset
-20.000...20.000
p4063[1] (0.000)
100 μs
A
+
+
D
(0)
TM31 AI T_smooth
0.0..1000.0 ms
p4053[1] (0.0)
0
x
-1
1
3
4
<2>
<3>
TM31 AI type
p4056[1] (4)
0
20 mA
1
<2>
<3>
TM31 AI inp_U/I
0, 2
r4052[1]
0
3
0
4 mA
4, 5
1
TM31 AI sim setp
TM31 AI sim_mode
-20.000...20.000
p4097[1] (0)
p4098[1] (0.000)
TM31 AI enable
p4069[1]
(1)
TM31 AI window
0.00...20.00 %
p4068[1] (0.00)
0
0 %
y = x if
y
|y - x| > p4068
1
otherwise y = y(alt)
5
fp_9568_51_eng.vsd
29.12.10 V04.07.00
p4099[1] (4000.00 μs)
TM31 WireBrkThresh
0.00...201 mA
p4061[1] (2.00)
0...1000 ms
p4062[1] (100)
3
20 mA
T
0
3
<2>
-20.000...20.000
-20.000...20.000
p4059[1] (10.000)
p4057[1] (0.000)
y
[%]
-1000.00...1000.00 %
y
p4060[1] (100.00)
2
x
x
1
-1000.00...1000.00 %
y
1
p4058[1] (0.00)
Scaling
Reference quantities
p2000...r2004
x
1
x
r4055[1]
x
2
x
x
1
2
100
%
<3> p4056
= 0: 0 V ... +10 V
= 2: 0 mA ... +20 mA
= 3: 4 mA ... +20 mA with monitoring
= 4: -10 V ... +10 V
= 5: -20 mA ... +20 mA
6
7
Function diagram
SINAMICS
F03505
"Analog input
wire break"
<2>
[%]
y
x
x
2
y
8
- 9568 -