Siemens SINAMICS G130 Manual De Listas página 1221

Ocultar thumbs Ver también para SINAMICS G130:
Tabla de contenido

Publicidad

Pulse enable via hardware
ASC/DCBRK act
r0046.4
p1230
(0)
Pulse inhibit (r0046.19 = 1)
r0046.20
Drive status S1, S2, S3, S4 not [2610]
1
2
DO: SERVO, VECTOR
Technology functions - External Armature Short-Circuit (EASC, p0300 = 2xx or 4xx)
p1231 = 1
Contactor feedback signal
1
p1235
Contactor
r0002 = 19
closed
1
r1239.0
p1236 = 200 ms
T
0
=1
p1237 = 200 ms
0
T
1
3
4
Control Unit
DI
DO
+24 V
&
&
Pulse enable via hardware
5
6
fp_7014_54_eng.vsd
20.12.13 V04.07.00
2000 μs
<1>
Drive converter
M
3
p1231 = 1
F07905
"Contactor feedback signal "Open" missing"
A07904
"Contactor feedback signal "Closed" missing"
p1231 = 2
7
8
Function diagram
- 7014 -
S120/S150/G130/G150

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sinamics g150

Tabla de contenido