Special Maintenance; General Cleaning - Moretti Forni P Classic Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

THE
FOLLOWING
MAINTENANCE" ARE STRICTLY RESERVED TO SPECIALIST TECHNICIANS
WITH THE RELEVANT LICENSE AS WELL AS BEING APPROVED BY THE
MANUFACTURER.
5

SPECIAL MAINTENANCE

5.1
PRELIMINARY SAFETY OPERATIONS
WARNING!
All maintenance operations and repairs must
be carried out using suitable accident prevention equipment, by
specialised and properly licensed technicians, approved by the
manufacturer.
Before performing any maintenance operation, disconnect the
power supply by turning off the switches fitted on the outside of the
oven and/or the leavening compartment.
All precautions are of importance to ensure that the oven remains
in a good state, and failure to observe them may result in serious
damage which will not be covered by the warranty.
WARNING!
Some operations, listed here below, need to be
carried out by at least two people.

5.2 GENERAL CLEANING

After carrying out the operations described in point 5.1 above, clean the
appliance as follows.
Regularly clean the appliance in general. After leaving it to cool down,
carefully remove, from internal and external parts, all residues that
might have collected during cooking, using a damp sponge or cloth and
a little soapy water, if necessary. Rinse and dry the areas, being sure to
wipe parts with satin finish in the direction of the finish.
WARNING!
Carefully clean off regularly any fat or grease
that may have dripped during cooking as this is a potential fire
hazard.
WARNING!
(P60E-P80E-P120E)
Depending on the use of the equipment should periodically remove
refractory or embossed sheet steel deck as indicated in paragraph
5.3.8 below and remove all the debris caused by cooking.
WARNING!
Never clean the appliance with direct jets of
water or with pressurised water jets. Do not allow water or any
cleansers used to come into contact with electrical parts.
The use of toxic or harmful detergents is prohibited.
NOTE:
Do not clean the tempered glass in doors while it is still
hot. Do not use solvents, detergents containing aggressive
substances (chlorides, acids, corrosives, abrasives, etc. ...) or
equipment that could damage surfaces. Before starting up the
appliance again, make sure that none of the cleaning equipment
has been left inside.
5.3
REPLACING PARTS OF THE BAKING CHAMBER
5.3.1
REPLACING THE LIGHT BULB
After carrying out the operations described in 5.1 above, to replace the
light bulb, proceed as follows from the inside of the baking chamber:
- Unscrew the cover (fig.21 item A) and replace the bulb (fig.21 item
B) and/or the cover.
- Replace the cover.
5.3.2
REPLACING THE DIGITAL PYROMETER
After carrying out the operations described in 5.1 above, to replace the
digital baking pyrometer proceed as follows:
- Unfasten the two fixing screws (plate A P60E-P80E) (plate B
Amalfi) (plate C P120E);
- Disconnect the pyrometer electrical connectors;
- Replace the pyrometer (item 25-27 plate A) (item 25 plate B) (item
17-19 plate C);
- Perform the above operations in reverse order to reassemble, taking
care that the connectors are inserted in the correct poles.
5.3.3
REPLACING THE THERMOCOUPLE
After carrying out the operations described in 5.1 above, to replace the
thermocouple proceed as follows:
WARNING
INSTRUCTIONS,
UK/8
WHICH
CONCERN
- Remove the side panel (item 29 plate A plate B) (item 22 plate C) by
unfastening the four fixing screws;
- Unfasten the thermocouple fixing nut;
- Disconnect the two wires feeding the thermocouple;
- Replace the thermocouple (item 45 plateA plateC) (item 43 plate B);
- Perform the above operations in reverse order to reassemble, taking
care that the connectors are inserted in the correct poles.
5.3.4
REPLACING THE TRANSFORMER
After carrying out the operations described in 5.1 above, to replace the
transformer proceed as follows:
- Remove the side panel by unfastening the four fixing screws;
- Disconnect the transformer electrical connections;
- Replace the transformer (item 43 plate A plate C) (item 41 plate B);
- Perform the above operations in reverse order to reassemble.
5.3.5
REPLACING THE TEMPERED GLASS
After carrying out the operations described in 5.1 above, to replace the
tempered glass proceed as follows:
- Remove the front fixing screws.
- Take off the front panel.
- Take off the front gasket.
- Replace the tempered glass, taking it out from the front;
- Replace the front and rear gaskets;
- Perform the above operations in reverse order to reassemble.
5.3.6
REPLACING THE HANDLE SPRING
After carrying out the operations described in 5.1 above, to replace the
handle spring proceed as follows:
- Remove the left side panel (item 29 plate A plate B) (item 22 plate
C) by unfastening the four fixing screws.
- Disconnect the spring (item 11 plate A) by unscrewing the two
fixing nuts.
- Replace the spring, using the two nuts to set the correct tension.
- Perform the above operations in reverse order to reassemble the
panel.
5.3.7
REPLACING THE HANDLE SPRING (P120E)
After carrying out the operations described in 5.1 above, to replace the
handle spring proceed as follows:
- Unscrew the digital pyrometer screws;
- Unscrew the digital pyrometer box screws;
- Unfasten the screws holding the right side panel;
- Lift the rock wool;
- Unfasten the nut holding the spring;
- Replace the spring (item 11 plate C);
- Perform the above operations in reverse order to reassemble.
5.3.8
REPLACING
THE
EMBOSSED SHEET STEEL DECK (P60E-P80E-P120E)
After carrying out the operations described in 5.1 above, to replace the
floor proceed as follows:
- Open the front door (plate A plate C);
- Lift the floor (item 54-55 plate A plate C) using a screwdriver as a
lever.
- Replace the floor.
5.3.9
REPLACING THE SAFETY THERMOSTAT
WARNING!
Regularly check that the safety thermostat is
operating correctly.
After carrying out the operations described in 5.1 above, to replace the
safety thermostat proceed as follows:
- Remove the two fixing screws (item 33 plate C) (item 32 plate B
Amalfi).
- Disconnect the thermostat faston connectors.
- Take off the right side panel by unfastening the four fixing screws;
- Remove the thermostat sensor, located inside the insulating rock
wool, using a blade to remove the section of rock wool involved;
"SPECIAL
REFRACTORY
FLOOR
OR

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

P classic amalfiP classic p60eP classic p80eP classic p120e

Tabla de contenido