MAKE THE ELECTRIC CONNECTIONS
Step 2. Motor to Receiver Electrical Connections: (Fig. 16) Connect the black
wire from the fan to the black wire marked "TO MOTOR L" on the receiver.
Connect the white wire from the fan to the white wire marked "TO MOTOR N" on
the receiver. Connect the blue wire from the fan to the blue wire marked "FOR
BOTTOM LIGHT" on the receiver. Connect the orange wire from the fan to the
orangewire marked "FOR UPPER LIGHT" on the receiver.
Secure each set of wire connections with the plastic wire nuts provided in the
parts bag.
Step 3. Receiver to Supply Wires ElectricalConnections: (Fig. 16) Connect the
black (load)wire from the ceiling outlet box to the black wiremarked "AC in L" on
the receiver.
Connect the white (neutral) wire from the ceilingoutlet box to the white wire
marked "AC in N" on the receiver.
Secure each set of electrical connections with the plastic wire nuts provided in
the parts bag.
Step 4. Connect the ground wire (green or barecopper) from the outlet box to
the ground wire on the ceiling mounting bracket and the ground wire from the
ceiling fan.
After making all connections, separate the whiteand green wire connections to
one side and the black wire connections to the other side of the outlet box.
NOTE: Fan must be installed at a maximum distance of 30 feet from the
CoolTouch™ Remote Transmitter for optimal signal transmission between the
transmitter and the fan's receiving unit.
14 | KICHLER.COM
Outlet box
Blac k (hot )
Blac k ("AC IN L" )
Receiver
Blac k ("to motor L" )
Blue (for bottom light)
Orange (for upper light)
Groun d
(green )
Orange (for upper light)
Blue (for bottom light)
Blac k (motor )
Fig. 16
Whit e (neutral )
Gree n or bar e
copper (ground )
Whit e ("AC IN N" )
Whit e ("to motor N" )
(Connect to
ground wir e on
hanger brack et
if no hous e
ground wir e
exists.)
Whit e (neutral )