MULTIJET PRO
8 – MEMO TEST
MEMO
With the MEMO, the user can select a previously memorized test.
Conduction:
1) Mount the injectors correctly (See item 3.5 - Assembly of injectors for test).
2) Through the keys
The Multijet will check the injectors resistance. The "", "INJ" and RPM icons will come on during this procedure.
The resistance values will be shown briefly for each injector. If any injector has resistance below 0.5 , the test will
be canceled and the message "not" will be displayed.
3) Will be available the selection of tests previously memorized. The number after the dash indicates the memory
to be selected . e.g.:
Through the keys
Memorized settings for the selected test will be displayed as follow:
RPM (Initial Value RPM 1 / Final Value RPM 2), test time ( "
("
" "
(ms)").
IF THE SELECTED MEMORY IS EMPTY (NO TEST MEMORIZED!)DISPLAYS THE MESSAGE
4)The 'connection safety alert' icon
locked. (This occurs in all injector tests as a form of prevention).
5) Press the Start/Cont key
pump and pressure adjustment.
If desired, adjust the pressure. The adjust procedure and security warnings are the same performed in previous
tests.
6) Press Start/Cont.
to start the test.
The display will indicate the start of the test with the letter "t". Before effective test, will occur a preamble, jets will
be generated by the injectors to remove the air from the circuit. During this procedure, the Drain is kept open.
During the test, the injectors frequency will be displayed (RPM - Rotacion per minute).
If the "10x" icon comes on, the user must multiply the number displayed by 10.
If necessary, the pressure can be adjusted during testing by the keys
A "beep" will occur at the end of test.
If necessary, drain the test fluid from the test tubes by the Drain key
after drainage, will turn it off automatically after 1 minute. The icon
To correctly remove the injectors, see chapter 12.0 - General Cares.
, select test "8" and press the Start
, test stored in the memory 1.
, select the memorized test and press Start/Cont
"
"
will blink in the panel, ensure that the hose connectors are connected and
and keep it pressed until there is a continous beep, allowing activation of the
26
.
.
." "
(seconds)"), injection time
.
.
. If the Drain is not manually turned off f
indicates Drain active.