MULTIJET PRO
5.1 - MOUNTING THE INJECTORS IN THE ULTRASOUND VAT
1) Fill the ultrasound vat up to the part indicated. Use Ultra Cleaner Bio correctly diluted as indicated on the item
3.2.
2) Connect the Injectors actuation cable to the Actuators Connector (front panel) and connect its plugs to the injectors
CABLES CONNECTION
(See chapter 3.4 -
Organize the injectors in the injectors support and thus fit in the ultrasound vat.
Injector
Injector support
5.2 - USING THE ULTRASOUND
The ultrasound is a system that interacts with all parts that are in contact with the vat , for this reason,
conditions that can cause variations in the normal work regime should be avoided.
They are:
-Lack of fluid inside the vat.
The volume must remain in the mark indicated. Due to several factors, the volume tends to reduce.
e.g.: water evaporation.
-Parts in direct contact with the vat, this overburdens the system and can cause irreversible
damages.
Always use the support provided.
5.3 - ULTRASOUND SYSTEM PROTECTION
The Multijet PRO is equipped with ultrasound protection system. Whenever there are persistent abnormalities
(e.g.: flow level below normal), the ultrasound will be disabled and will remain thus until the system returns to
the normal regime.
Once activated, the protection will display the message "
ultrasound whenever there are attempts to use it.
ATENÇÃO ! /ATENCIÓN! /CAUTION !
MANTER O NÍVEL SEMPRE NESTA MARCA
MANTENER EL NIVEL SIEMPRE EN LA MARCA
KEEP LEVEL ON THE MARK
).
30
". Indicating unavailability of