MULTIJET PRO
9.0 - MEMO FUNCTION (MEMORY / MEMORIZING A TEST)
The Multijet PRO can store up to 9 types of tests programmed by the user.
The MEMO key
will execute the memory operation whenever there is no test in progress.
To store a test programmed by the user, the function 9 (PROG) must be the immediately preceding operation,
otherwise, the comand is not executed.
(For more information on how to program and use test 9 (PROG), see the chapter 4.3 - Injector test / 9 – PROG
Test).
Conduction:
1) Through the keys
Make all settings of your preference, set the initial and final RPM frequency, the test duration, injector opening time
and pressure.
Conduct the test normally.
At the end of the test, the Multijet PRO will echo a "beep", indicating that the test was concluded.
2) If the test proceeds exactly as desired by the user, save it in the memory, otherwise, redo step 1.
To save, press and keep pressed the MEMO key
The letter "M" will appear in the display, followed by a hyphen and a number. The number after the hyphen
represents the position of the test to be memorized.. e.g.:
NOTE: This test can be used later when selected test
3) Through the keys
4) To confirm, press and keep pressed the MEMO key
has been stored in the Multijet PRO.
9.1 - MODIFYING A SAVED TEST
To change one of the tests saved in the memory, just perform the procedure described above.
There is no option to erase or protect stored tests, the test already saved at the selected memory will simply be
overwritten.
ENSURE THAT THE TEST NUMBER YOU CHOSE IS EXACTLY THE TEST YOU WISH TO
MODIFY, BECAUSE, ONCE CHANGED, IT IS IMPOSSIBLE TO REVERT THE OPERATION.
, select the test "9" and press the Start/Cont.
until occur a continuous "beep".
, select the number from 1 to 9, where you wish to save the test.
until occur a continous "beep" . Ready! The test
38
.
.
.