Cleaning Process; Injector Cleaning - alfatest Multijet Pro Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.4 - CLENING PROCESS
11 – INJECTORS CLEANING
The cleaning is done through the ultrasound system and pulsation*.
Conduction:
1)Mount the injectors in the ultrasound vat correctly (
ULTRASOUND VAT)
Note: Electric injectors actuation exist only if the ultrasound is active.
2) Through the keys
function started and or active.
3) Select the cleaning time (1 to 90 minutes), use the keys
4) To start the cleaning, press the Start/Cont.
The Multijet PRO will start emitting ultrasound waves and electric pulses through the Injector actuation cable.
There is no resistance reading, it is therefore advisable to conduct an injector test before the cleaning.
If necessary, through the keys
is not necessary stop or pause the cleaning.
During the cleaning will be displayed contdown time set. If other function are active, use the key "FUNCTION" to
select the Ultrasound control (icon
A "beep" will occur at the end of cleaning.
* The pulse (electric actuation) during cleaning is optional, however, is advisable as it helps in the shedding of
particles.
If desired actuation during the cleaning, connect the injector's cable (equal to that used for the tests) in the connector
actuators / injectors(cleaning by ulrasound). See item 3.4 - CABLES CONEXION.
To test and clean(with electrical actuation) injectors simultaneously, are needed to use two injector's cable.
See item 5.1 - MOUNTING THE INJECTOR IN THE
, select the option "11" and press Start/Cont.
.
is possible to readjust the uptime of the process during ultrasound. It
on).