Chapter 4
WARNING
3 0 6
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Installation
4
Installation
4.1
IP 20 version
Use IP-20 housing only for cabinet installation!
The IP-20 housing must only be used for installation in a control
cabinet.
The housing of the IP 20 version is clipped onto a DIN mounting
rail.
4.2
IP 65 version
1 . Use a screwdriver to open the hinged clip locks a and remove
the front section of the housing s (see Fig. 4-1).
Fig. 4-1: IP 65 housing, removing the front section of the housing
F = Front section
2 . Drill holes for the housing fixing screws (the base section can be
used as a template).
3 . Screw on the base section.
4 . Place the front section on the base section and secure using
the hinged clip locks.
B = Base section
Operating Instructions
Safety Evaluation Unit LE 20
8 008 685/Q913/2007-05-21