If your furnace fails to work correctly, you may avoid the inconvenience
and cost of a service call by checking the troubleshooting section on
page 40 before you call for service.
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
DO NOT store or use gasoline or other flammable vapors and
liquids in the vicinity or this or any other appliance.
HOW TO ORDER REPAIR PARTS
When ordering repair parts, always give the following Information:
1.
MODEL NUMBER
2.
MFG. DATE CODE
3.
PART NUMBER
4.
PART DESCRIPTION
All installations in the State of Massachusetts must use the
following requirements when installing, maintaining or operating
direct-vent propane or natural gas-fired space heaters.
For direct-vent appliances, mechanical-vent heating appliances
or domestic hot water equipment, where the bottom of the vent
terminal and the air intake is installed below four feet above
grade the following requirements must be satisfied:
1. If there is not one already present, on each floor level where
there are bedroom(s), a carbon monoxide detector and alarm
shall be placed in the living area outside the bedroom(s).
The carbon monoxide detector shall comply with
NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall be located in the room that
houses the appliance or equipment and shall:
a. Be powered by the same electrical circuit as the appliance
or equipment such that only one service switch services both
the appliance and the carbon monoxide detector.
b. Have battery back-up power;
c. Meet ANSI/UL 2034 Standards and comply with
NFPA 720 (2005 Edition); and
Cozy Heating Systems | cozyheaters.com | 888-444-1212 | 250 West Laurel Street | Colton, CA 92324
HINTS AND INFORMATION
INSTALLATIONS IN THE STATE OF MASSACHUSETTS
Subject to change without notice | © 2021
All parts listed herein may be ordered from your equipment supplier.
The Model Number of your Cozy wall furnace will be found on the
nameplate near gas valve, inside control compartment.
WHAT TO DO IF YOU SMELL GAS
Open all of the windows.
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone or cell phone in your building.
Extinguish any open flame.
Immediately call your gas supplier from a neighbor s
phone. If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
d. Have been approved and listed by a Nationally Recognized
Testing Laboratory as recognized under 527 CMR.
A CARBON MONOXIDE DETECTOR SHALL:
a. Be located in the room that houses the appliance or
equipment;
b. Be either hard-wired or battery powered or both; and
c. Shall comply with NFPA 720 (2005 Edition).
3. A product-approved vent terminal must be used, and
if applicable, a product-approved air intake must be used.
Installation shall be in strict compliance with the manufacturer s
instructions. A copy of the installation instructions shall remain
with the appliance or equipment at the completion of
the installation.
4. A metal or plastic identification plate shall be mounted at the
exterior of the building, four feet directly above the
location of vent terminal. The plate shall be of sufficient
size to be easily read from a distance of eight feet
away, and read Gas Vent Directly Below .