Oil draining
We advise to change oil after 10000 hours of running.
In order to remove all residual particles in oil, do not hesitate to:
-
Run the unit before draining in order to reduce the viscosity of the old lubricant
"Wash" the unit with fresh oil before refilling.
-
1. Unscrew the 2 oil input plugs of the DRP+ to allow air entering the gearbox.
2. Unscrew the 4 oil output plugs (2 per circuit) and wait until no more oil flows out from the unit.
NOTE:
Drained oil is a special industrial waste and should be handled according to current laws.
The following drawings show the exact location of the lubrication holes.