Configuration:
Accessories:
Sightglass
(1per circuit)
Up
Down
Size
DRP1+R/P
DRP2+R/P
DRP3+R/P
DRP4+R/P
DRP5+R/P
WARNING!
External forced lubrication: special procedure.
For each lubrication circuit:
1. Connect the external lubrication pipes and fill them with oil. The oil suction is located in the bottom
hole of the bevel box and the oil injection in the upper hole of the DPR+ housing.
2. Adjust the oil level to the middle of the sight glass while the pump is not running.
3. Run the pump and re-adjust the oil level to the middle of the sight glasses while the pump is running.
Notes:
The breathers are not necessary.
Oil must be filtered (< 50µm).
Internal pressure must not exceed 1 bar.
This document must not be reproduced nor information therein disclosed without our authorization