36 | EPS 205 | Maintenance
8.
Maintenance
8.1
Cleaning
Clean the guard with a damp cloth (water and deter-
gent only) or using a plastics cleaning agent.
!
The guard is not to be cleaned using alcohol-based
cleaning agents such as glass cleaners.
Only use a soft cloth and neutral detergents to clean
the vent grille, housing and LCD of the EPS 205. Do
not use abrasive cleaning agents and coarse workshop
cloths. Always use clean cloths for cleaning the LCD.
8.2
Service
As is the case with all technical devices, the EPS 205
requires expert servicing at regular intervals. The inter-
vals given apply to operation of the EPS 205 for 8 hours
per day.
8.2.1
Service intervals
Work to be performed
Leak test
(see Online Help)
Cleaning of vent grilles (see Sec. 8.1)
Replacement of high-pressure hose
(see Sec. 8.2.2)
Checking of hoses (see Sec. 8.2.3)
Check the protective hood contact
(see Sec. 8.2.4)
Cleaning of jet chamber and ring
lamp cover (see Sec. 8.2.5)
Changing of test oil and cleaning of
tank
(see Sec. 8.2.6)
1)
Replacement of intake filter in test oil
tank
(see Sec. 8.2.7)
2)
Replacement of flowmeter pipe fil-
ter
(see Sec. 8.2.8)
1)
Checking of toothed belt
(see Sec. 8.2.9)
Replacement of toothed belt
3)
(see Sec. 8.2.10)
Replacement of inlet filter element
(see Sec. 8.2.11)
Replacing the strainer of the change-
over valve
(see sec. 8.2.12)
4)
To be performed by the customer
*)
To be performed by the Testing department/Customer service
**)
during main inspection
Every 3 months or after 200 injector tests
1)
Once a year or after 1500 injector tests
2)
Every 2 years of after 3000 injector tests
3)
Once a week or after testing 30 cleaned injectors
4)
|
1 689 989 186
2017-10-27
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
4)
X
X
X
8.2.2
Replacing high-pressure hose
Replace high-pressure hoses (operating pressure great-
er than 60 bar) after 3 years (see date of manufacture
on high-pressure hose) even if there are no apparent
defects of relevance to safety.
The high-pressure hose (Fig. 1, item 10) is only to be
replaced by Customer service personnel.
8.2.3
Checking hoses
Always handle hoses (high-pressure and low-pressure
hoses) with care and check before use. Hoses are to be
replaced if checking reveals the following signs of dam-
age:
R
Cracks, brittle areas, abrasion or blistering at the
hose jacket
R
Kinked hoses
R
Stiff union nuts or quick-release couplings
R
Deformed or damaged hose connection end (seal-
ing cone, plug-in nipple, etc.)
R
Leakage at fitting
R
Corrosion at fitting if strength is reduced as a result
!
Damaged hoses are not to be repaired.
8.2.4
Check the protective hood contact
Injection component test must be carried out only with
the protective hood closed. That is why, the protective
hood contact must be checked every day.
1. Start a component test with the protective hood
open.
Diagnostic trouble code: 9005 Protec-
tive hood appears to be open.
2. Close the protective hood.
 Diagnostic trouble code no longer appears.
 Injection component test can be carried out.
8.2.5
Cleaning jet chamber and ring lamp cover
Clean the jet chamber with a clean cloth to remove
coarse dirt. Wipe over the ring lamp cover inside the jet
chamber with a clean cloth as required.