(6) Position of the presser foot and the needle entry point

WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of
the sewing machine.
A
2
0 to 0.5 mm

(7) Adjusting the knife dropping position

WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of
the sewing machine.
1
2
3
0
B
3
1
3
4
3
Adjust the clearance between the presser
foot and the holding plate to 0 to 0.5 mm.
Loosen two setscrews 1 n the presser arm base
and the adjust the clearance. Then fx the presser
arm n place.
Moving presser arm 2 in the direction A will
reduce the clearance between the presser
foot and the outside needle entry point.
* The front or rear nclnaton can be adjusted wth
presser arm setscrew 3 .
Upper knife type
Loosen setscrew 1 n the cloth cuttng knfe
nstallng base, adjust cloth cuttng knfe nstallng
base 2 to the left or right. Then fix the base.
Lower knife type
Loosen setscrews 3 n the knfe base and adjust
knfe base 4 to the left or right. Then fix the knife
base.