12. EXCHANGING GAGUE PARTS AND OPTIONAL
(1) Changing the thread trimming method
■ DIP switch
Thread trmmng type s selected wth DIP swtch 1 and 2 located at the rear of the machne head.
It is necessary to separately set the memory switch (machine model setting) in case of the change of
type such as S ←→ J and the like.
1) S and R type (long thread trmmng)
Do not change DIP-SW for the long thread trimming type.
2) J and C type (short thread trmmng)
DIP-SW
1
ON
OFF
ON
Simultaneously change DIP-SW when changing the presser set for J and C types.
When changing the presser set, the pattern used before the change cannot be used.
3) T type (short thread trmmng wthout gmp) – for slacks
DIP-SW
1
OFF
Do not change DIP-SW for the short thread trimming without gimp type.
0
Presser type
2
OFF
S
ON
M
ON
L
Type
2
3
Short thread trmmng
wthout gmp
OFF
ON
DIP-SW
1
OFF
Long thread trimming
Short thread
Short thread
trimming S
trimming M
(C standard)
(J standard)
Type
2
Long thread
trmmng
OFF
Short thread
trimming L