Yamaha WaveRunner FX140 Manual De Servicio página 556

Ocultar thumbs Ver también para WaveRunner FX140:
Tabla de contenido

Publicidad

+
ELEC
IGNITION SYSTEM
THERMOSWITCH (ENGINE)
1. Check:
• Thermoswitch (engine) continuity
(at the specified temperature)
Out of specification → Replace.
Thermoswitch (engine) continuity
temperature:
a 84–90 °C (183–194 °F)
b 70–84 °C (158–183 °F)
1 No continuity
2 Continuity
Checking steps:
• Suspend the thermoswitch (engine) in a
container filled with water.
• Place a thermometer in the water.
• Slowly heat the water.
• Measure the continuity when the speci-
fied temperature is reached.
THERMOSWITCH (EXHAUST)
1. Check:
• Thermoswitch (exhaust) continuity
(at the specified temperature)
Out of specification → Replace.
Thermoswitch (exhaust)
continuity temperature:
a 94–100 °C (201–212 °F)
b 80–94 °C (176–201 °F)
1 No continuity
2 Continuity
Checking steps:
• Suspend the thermoswitch (exhaust) in a
container filled with water.
• Place a thermometer in the water.
• Slowly heat the water.
• Measure the continuity when the speci-
fied temperature is reached.
7-22
E
È Temperature
É Time
È Temperature
É Time

Publicidad

Tabla de contenido
loading

Tabla de contenido